Deep learning image reconstruction (DLIR) algorithms employ convolutional neural networks (CNNs) for CT image reconstruction to produce CT images with a very low noise level, even at a low radiation d...
Dynamic myocardial computed tomography perfusion (CTP) is a novel technique able to depict cardiac ischemia....
To evaluate the impact of a four-dimensional noise reduction filter (similarity filter [4D-SF]) on image quality in dynamic CTP imaging, allowing for substantial radiation dose reduction....
Dynamic CTP datasets of 30 patients (16 women) with suspected coronary artery disease, acquired with a 320-slice CT system, were retrieved, reconstructed with the deep learning-based algorithm of the ...
Mean SNR in four-chamber view (unfiltered vs. filtered) were: septum=4.1 ± 2.1 versus 7.6 ± 5.6; lateral wall=4.5 ± 2.0 versus 8.0 ± 4.9; CNRseptum=16.6 ± 8.9 versus 31.7 ± 28; lateral wall=16.2 ± 8.9...
Similarity filtering after DLR improves image quality, possibly enabling dose reduction in dynamic CTP imaging in patient with suspected chronic coronary syndrome....
Quantitative computed tomography (CT) plays an increasingly important role in phenotyping airway diseases. Lung parenchyma and airway inflammation could be quantified by contrast enhancement at CT, bu...
For this cross-sectional retrospective study, 234 lung-healthy patients who underwent spectral CT in four different contrast phases (non-enhanced, pulmonary arterial, systemic arterial, and venous pha...
Mean lung density was higher at 40 keV compared to that at 100 keV in all groups (p < 0.001). λHU of lung attenuation was significantly higher in the systemic (1.7 HU/keV) and pulmonary arterial phase...
Spectral CT may quantify lung parenchyma and airway wall enhancement with a single contrast phase acquisition, and may separate arterial and venous enhancement. Further studies are warranted to analyz...
• Spectral CT may quantify lung parenchyma and airway wall enhancement with a single contrast phase acquisition. • Spectral CT may separate arterial and venous enhancement of lung parenchyma and airwa...
The analysis of the psoas muscle in morphological and functional imaging has proved to be an accurate approach to assess sarcopenia, i.e. a systemic loss of skeletal muscle mass and function that may ...
To evaluate the depiction of wrist tendons in virtual monochromatic images (VMIs) during a dual-energy CT (DE-CT) with the VMI image of conventional equivalent to 120 kVp....
Using Catphan600 and phantom analysis software for CT evaluation, measurements of VMI in a DE-CT were performed corresponding to the tube voltages of single-energy CT at 120 kVp. Using a Discovery CT7...
The highest CT number and CNR for the tendon were for the 140 keV VMI in the DE-CT compared to the other energy levels. There were significantly higher CT numbers, CNR values, and visual scores for ea...
Energy level of the VMIs during DE-CT for the best wrist tendon delineation was 140 keV. This value of 140 keV for the DE-CT was significantly higher than the CT number and CNR for the extensor pollic...
To investigate the image quality of lower extremity computed tomography angiography (LE-CTA) using a reconstruction algorithm for monoenergetic images (MEIs) to evaluate peripheral arterial disease (P...
A total of 146 consecutive patients who underwent LE-CTA on a dual-energy scanner to obtain MEIs at 40, 50, 60, 70, and 80 keV were included. The overall image quality, segmental image quality of the ...
The mean overall image quality of each MEI was 2.9 ± 0.7, 3.6 ± 0.6, 3.9 ± 0.3, 4.0 ± 0.2, and 4.0 ± 0.2 from 40 to 80 keV, respectively. The segmental image quality gradually increased from 40 to 70-...
The LE-CTA method using a reconstruction algorithm for MEIs at 70-80 keV can enhance the image quality for PAD evaluation and improve mitigate venous contamination and metal artifacts....
Acute ischemic lesions are challenging to detect by conventional computed tomography (CT). Virtual monoenergetic images may improve detection rates by increased tissue contrast....
To compare the ability to detect ischemic lesions of virtual monoenergetic with conventional images in patients with acute stroke....
We included consecutive patients at our center that underwent brain CT in a spectral scanner for suspicion of acute stroke, onset <12 h, with or without (negative controls) a confirmed cortical ischem...
In total, 29 patients were included (January 2018 to July 2019). SNR was higher in virtual monoenergetic compared to conventional images, significantly at 60-150 keV. CNR between ischemic gray and nor...
Virtual monoenergetic reconstructions of spectral CIs may improve image quality and diagnostic ability in stroke assessment....
This study aimed to compare the performance of deep learning image reconstruction (DLIR) and adaptive statistical iterative reconstruction-Veo (ASIR-V) in improving image quality and diagnostic perfor...
Prostate cancer is one of the most common malignant tumors in middle-aged and elderly men and carries significant prognostic implications, and recent studies suggest that dual-energy computed tomograp...
We conducted a retrospective analysis of 83 patients with prostate cancer or prostatic hyperplasia who underwent DECT scans at Meizhou People's Hospital between July 2019 and December 2023. The variab...
Virtual monoenergetic images at 40 keV showed significantly higher CT values (168.19 ± 57.14) compared to conventional linear blending images (66.66 ± 15.5) for prostate cancer (P < 0.001). The 50 keV...
Virtual monoenergetic images reconstructed at 40 keV and 50 keV from DECT arterial phase scans substantially enhance the image quality of prostate lesions and improve diagnostic efficacy for prostate ...
Reduction in iodinated contrast medium (CM) dose is highly motivated. Our aim was to evaluate if a 50% reduction of CM, while preserving image quality, is possible in brain CT angiography (CTA) using ...
Consecutive patients older than 18 years without intracranial stenosis/occlusion were included. Three imaging protocols were used: group 1, full CM dose; group 2, 50% CM dose suboptimal timing; and gr...
Qualitatively and quantitatively, VMI (40-60 keV) improved image quality within each group. Significantly higher attenuation and CNR was found for group 3 VMI 40-50 keV, with unchanged SNR, compared t...
VMI of 50 keV with 50% CM dose increases qualitative and quantitative image quality over CI with full CM dose. Using VMI reduces non-diagnostic examinations and may salvage CTA examinations deemed non...