Artificial intelligence-assisted interpretation of bone age radiographs improves accuracy and decreases variability.
Augmented intelligence
Bone age
Machine learning
Pediatric
Radiographs
Journal
Skeletal radiology
ISSN: 1432-2161
Titre abrégé: Skeletal Radiol
Pays: Germany
ID NLM: 7701953
Informations de publication
Date de publication:
Feb 2019
Feb 2019
Historique:
received:
12
05
2018
accepted:
20
07
2018
revised:
10
07
2018
pubmed:
3
8
2018
medline:
25
1
2019
entrez:
3
8
2018
Statut:
ppublish
Résumé
Radiographic bone age assessment (BAA) is used in the evaluation of pediatric endocrine and metabolic disorders. We previously developed an automated artificial intelligence (AI) deep learning algorithm to perform BAA using convolutional neural networks. We compared the BAA performance of a cohort of pediatric radiologists with and without AI assistance. Six board-certified, subspecialty trained pediatric radiologists interpreted 280 age- and gender-matched bone age radiographs ranging from 5 to 18 years. Three of those radiologists then performed BAA with AI assistance. Bone age accuracy and root mean squared error (RMSE) were used as measures of accuracy. Intraclass correlation coefficient evaluated inter-rater variation. AI BAA accuracy was 68.2% overall and 98.6% within 1 year, and the mean six-reader cohort accuracy was 63.6 and 97.4% within 1 year. AI RMSE was 0.601 years, while mean single-reader RMSE was 0.661 years. Pooled RMSE decreased from 0.661 to 0.508 years, all individually decreasing with AI assistance. ICC without AI was 0.9914 and with AI was 0.9951. AI improves radiologist's bone age assessment by increasing accuracy and decreasing variability and RMSE. The utilization of AI by radiologists improves performance compared to AI alone, a radiologist alone, or a pooled cohort of experts. This suggests that AI may optimally be utilized as an adjunct to radiologist interpretation of imaging studies to improve performance.
Identifiants
pubmed: 30069585
doi: 10.1007/s00256-018-3033-2
pii: 10.1007/s00256-018-3033-2
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
275-283Références
Comput Med Imaging Graph. 2000 Sep-Oct;24(5):297-307
pubmed: 10940607
IEEE Trans Med Imaging. 1989;8(1):64-9
pubmed: 18230501
IEEE Trans Med Imaging. 2009 Jan;28(1):52-66
pubmed: 19116188
IEEE Trans Med Imaging. 2016 May;35(5):1273-1284
pubmed: 26886969
IEEE J Transl Eng Health Med. 2015 Apr 03;3:2900310
pubmed: 27170906
JAMA. 2016 Dec 13;316(22):2402-2410
pubmed: 27898976
Nature. 2017 Feb 2;542(7639):115-118
pubmed: 28117445
J Digit Imaging. 2017 Aug;30(4):427-441
pubmed: 28275919
Radiology. 2017 Aug;284(2):574-582
pubmed: 28436741
J Digit Imaging. 2017 Aug;30(4):487-498
pubmed: 28653123
Am J Respir Crit Care Med. 2018 Jan 15;197(2):193-203
pubmed: 28892454
AJR Am J Roentgenol. 2017 Dec;209(6):1374-1380
pubmed: 28898126
Radiology. 2018 Mar;286(3):810-818
pubmed: 29039725
Nature. 2017 Oct 18;550(7676):354-359
pubmed: 29052630
Radiology. 2018 Apr;287(1):313-322
pubmed: 29095675
Br J Radiol. 1994 Sep;67(801):848-51
pubmed: 7953224