Development of a strategy for the quantification of food allergens in several food products by mass spectrometry in a routine laboratory.


Journal

Food chemistry
ISSN: 1873-7072
Titre abrégé: Food Chem
Pays: England
ID NLM: 7702639

Informations de publication

Date de publication:
15 Feb 2019
Historique:
received: 05 04 2018
revised: 16 08 2018
accepted: 21 08 2018
entrez: 31 10 2018
pubmed: 31 10 2018
medline: 26 12 2018
Statut: ppublish

Résumé

Worldwide, mass spectrometry is widely used to detect and quantify food allergens, especially in complex and processed food products. Yet, the absence of a regulatory framework for the developed methods has led to a lack of harmonization between laboratories. In this study, ten allergens were analyzed in eight food products by UHPLC-MS/MS, in order to establish criteria for the retention time, variation tolerance, the ion ratio deviation, and the signal-to-noise ratio for allergen detection. The set of criteria should help laboratories to compare results and avoid false positives and negatives. Furthermore, a strategy combining standard addition and labeled peptide correction was used to quantify milk, soy, peanut, and egg allergens in eight food products. This strategy is particularly interesting for routine laboratories, which receive hundreds of samples and cannot use an external calibration curve for each sample.

Identifiants

pubmed: 30372950
pii: S0308-8146(18)31508-5
doi: 10.1016/j.foodchem.2018.08.095
pii:
doi:

Substances chimiques

Allergens 0
Peptides 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

35-45

Informations de copyright

Copyright © 2018 Elsevier Ltd. All rights reserved.

Auteurs

M Planque (M)

CER Groupe, Health Department, rue du Point du Jour, 8, 6900 Marloie, Belgium; Laboratory of Biochemistry and Cell Biology (URBC)-Namur Research Institute for Life Sciences (NARILIS), University of Namur, 61, rue de Bruxelles, 5000 Namur, Belgium.

T Arnould (T)

Laboratory of Biochemistry and Cell Biology (URBC)-Namur Research Institute for Life Sciences (NARILIS), University of Namur, 61, rue de Bruxelles, 5000 Namur, Belgium.

P Delahaut (P)

CER Groupe, Health Department, rue du Point du Jour, 8, 6900 Marloie, Belgium.

P Renard (P)

Laboratory of Biochemistry and Cell Biology (URBC)-Namur Research Institute for Life Sciences (NARILIS), University of Namur, 61, rue de Bruxelles, 5000 Namur, Belgium.

M Dieu (M)

Laboratory of Biochemistry and Cell Biology (URBC)-Namur Research Institute for Life Sciences (NARILIS), University of Namur, 61, rue de Bruxelles, 5000 Namur, Belgium.

N Gillard (N)

CER Groupe, Health Department, rue du Point du Jour, 8, 6900 Marloie, Belgium. Electronic address: n.gillard@cergroupe.be.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH