Résumé
Implantable continuous-flow left ventricular assist devices (CF-LVADs) are used for long-term LV support in bridging patients to heart transplantation or as destination therapy. With prolonged support times, some patients will have repeat complications necessitating multiple device exchanges. To elucidate the safety and efficacy of repeat device exchange, we retrospectively reviewed data from 25 patients who underwent two or more CF-LVAD implantations between July 2005 and August 2017. Indications for exchange were thrombus/hemolysis (n = 8, 32%), electromechanical device malfunction (n = 14, 56%), and infection (n = 3, 12%). The implanted devices were the HeartMate II (n = 13, 52%), the HeartWare HVAD (n = 11, 44%), and the Jarvik 2000 (n = 1, 4%). Average hospital length of stay was 44 days (range 4-221 days), and 17 patients (68%) survived to discharge. Average duration of support after the most recent LVAD implantation was 802 days (range 1-3,229 days). Overall survival was 72% at 1 year and 60% at 2 years. Postoperative complications included respiratory failure in five patients (20%), device infection in five (20%), bleeding requiring reoperation in four (16%), neurologic dysfunction in four (16%), and acute renal failure in two (8%). Overall, our data suggest that repeat LVAD exchange is a feasible option for patients with recurrent device-related complications.
Identifiants
pubmed: 30507849
doi: 10.1097/MAT.0000000000000928
pii: 00002480-202001000-00010
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
64-68Commentaires et corrections
Type : CommentIn
Références
Anand J, Singh SK, Hernández R, et al. Continuous-flow ventricular assist device exchange is safe and effective in prolonging support time in patients with end-stage heart failure. J Thorac Cardiovasc Surg 2015.149: 267–275, 278.e1
Kirklin JK, Naftel DC, Kormos RL, et al. Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transplant 2013.32: 141–156
Slaughter MS, Rogers JG, Milano CA, et al.; HeartMate II Investigators: Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009.361: 2241–2251
Kirklin JK, Pagani FD, Kormos RL, et al. Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. J Heart Lung Transplant 2017.36: 1080–1086
Stulak JM, Cowger J, Haft JW, Romano MA, Aaronson KD, Pagani FD. Device exchange after primary left ventricular assist device implantation: Indications and outcomes. Ann Thorac Surg 2013.95: 1262–1267
Radwan M, Risteski P, Hoffmann R, Popov AF. Repeat left ventricular assist device exchange with inflow or outflow correction for recurrent pump thrombosis and cerebral haemorrhage through limited incisions. Eur J Cardiothorac Surg 2018.54: 781–783
Sabashnikov A, Butters T, Högerle B, et al. Around and around the merry-go-round: Multiple implantations of short- and long-term ventricular assist devices in a patient with severe heart failure. J Artif Organs 2015.18: 166–169
Kirklin JK, Naftel DC, Kormos RL, et al. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device. J Heart Lung Transplant 2014.33: 12–22
Goldstein DJ, John R, Salerno C, et al. Algorithm for the diagnosis and management of suspected pump thrombus. J Heart Lung Transplant 2013.32: 667–670
Takeda K, Takayama H, Kalesan B, et al. Long-term outcome of patients on continuous-flow left ventricular assist device support. J Thorac Cardiovasc Surg 2014.148: 1606–1614
Gregoric ID, Bruckner BA, Jacob L, et al. Clinical experience with sternotomy versus subcostal approach for exchange of the HeartMate XVE to the HeartMate II ventricular assist device. Ann Thorac Surg 2008.85: 1646–1649
Nishimura T, Ota T, Takayama H, Naka Y. Subcostal to rib-cross incision for HeartMate II explantation: A case report. J Thorac Cardiovasc Surg 2013.145: e16—e17
Ota T, Yerebakan H, Akashi H, et al. Continuous-flow left ventricular assist device exchange: Clinical outcomes. J Heart Lung Transplant 2014.33: 65–70
Soleimani B, Stephenson ER, Price LC, El-Banayosy A, Pae WE. Clinical experience with sternotomy versus subcostal approach for exchange of HeartMate II left ventricular assist device. Ann Thorac Surg 2015.100: 1577–1580
Sugiura T, Kurihara C, Kawabori M, et al. Comparison of sternotomy versus a subcostal approach for exchange of HeartMate II continuous flow-left ventricular assist device. J Heart Lung Transplant 2018.37: S271–S272