Outcomes Among Patients With Heart Failure With Reduced Ejection Fraction Undergoing Transcatheter Aortic Valve Replacement: Minimally Invasive Strategy Versus Conventional Strategy.
Aged
Aged, 80 and over
Aortic Valve Stenosis
/ diagnostic imaging
Cardiac Catheterization
/ methods
Cardiac Output, Low
/ diagnostic imaging
Cohort Studies
Conscious Sedation
/ methods
Echocardiography, Transesophageal
/ methods
Female
Heart Failure
/ diagnosis
Hospital Mortality
Humans
Length of Stay
Logistic Models
Male
Minimally Invasive Surgical Procedures
/ methods
Multivariate Analysis
Prognosis
Reference Values
Retrospective Studies
Risk Assessment
Severity of Illness Index
Surgery, Computer-Assisted
/ methods
Survival Rate
Transcatheter Aortic Valve Replacement
/ methods
Treatment Outcome
anesthesia
aortic stenosis
conscious sedation
heart failure
transcatheter aortic valve replacement
Journal
The Journal of invasive cardiology
ISSN: 1557-2501
Titre abrégé: J Invasive Cardiol
Pays: United States
ID NLM: 8917477
Informations de publication
Date de publication:
03 2019
03 2019
Historique:
pubmed:
18
12
2018
medline:
18
12
2019
entrez:
18
12
2018
Statut:
ppublish
Résumé
To investigate the effect of TAVR technique on in-hospital and 30-day outcomes in patients with aortic stenosis (AS) and reduced ejection fraction (EF). Patients with AS and concomitant low EF may be at risk for adverse hemodynamic effects from general anesthesia utilized in transcatheter aortic valve replacement (TAVR) via the conventional strategy (CS). These patients may be better suited for the minimally invasive strategy (MIS), which employs conscious sedation. However, data are lacking that compare MIS to CS in patients with AS and concomitant low EF. In this retrospective study, we identified all patients with low EF (<50%) undergoing transfemoral MIS-TAVR vs CS-TAVR between March 2011 and May 2018. Our primary endpoint was defined as the composite of in-hospital mortality and major periprocedural bleeding or vascular complications. Two hundred and seventy patients had EF <50%, while 154 patients had EF ≤35%. Overall, a total of 236 patients were in the MIS group and 34 were in the CS group. Baseline characteristics between the two groups were similar except for Society of Thoracic Surgeons (STS) score (MIS 8.4 ± 5.1 vs CS 11.7 ± 6.8; P<.01). There were no differences between the two groups in incidence of the primary endpoint (MIS 5.5% vs CS 8.8%; odds ratio for MIS, 0.60; 95% confidence interval, 0.16-2.23; P=.45). In patients with severe AS and reduced EF, MIS was not associated with adverse in-hospital or 30-day clinical outcomes compared with CS. In these patients, MIS may be a suitable alternative to CS without compromising clinical outcomes.
Sections du résumé
OBJECTIVES
To investigate the effect of TAVR technique on in-hospital and 30-day outcomes in patients with aortic stenosis (AS) and reduced ejection fraction (EF).
BACKGROUND
Patients with AS and concomitant low EF may be at risk for adverse hemodynamic effects from general anesthesia utilized in transcatheter aortic valve replacement (TAVR) via the conventional strategy (CS). These patients may be better suited for the minimally invasive strategy (MIS), which employs conscious sedation. However, data are lacking that compare MIS to CS in patients with AS and concomitant low EF.
METHODS
In this retrospective study, we identified all patients with low EF (<50%) undergoing transfemoral MIS-TAVR vs CS-TAVR between March 2011 and May 2018. Our primary endpoint was defined as the composite of in-hospital mortality and major periprocedural bleeding or vascular complications.
RESULTS
Two hundred and seventy patients had EF <50%, while 154 patients had EF ≤35%. Overall, a total of 236 patients were in the MIS group and 34 were in the CS group. Baseline characteristics between the two groups were similar except for Society of Thoracic Surgeons (STS) score (MIS 8.4 ± 5.1 vs CS 11.7 ± 6.8; P<.01). There were no differences between the two groups in incidence of the primary endpoint (MIS 5.5% vs CS 8.8%; odds ratio for MIS, 0.60; 95% confidence interval, 0.16-2.23; P=.45).
CONCLUSIONS
In patients with severe AS and reduced EF, MIS was not associated with adverse in-hospital or 30-day clinical outcomes compared with CS. In these patients, MIS may be a suitable alternative to CS without compromising clinical outcomes.