Résumé
While multiple trials have employed stereotactic stem cell transplantation, injection techniques have received little critical attention. Precise cell delivery is critical for certain applications, particularly when targeting deep nuclei. Ten patients with a history of ischemic stroke underwent CT-guided stem cell transplantation. Cells were delivered along 3 tracts adjacent to the infarcted area. Intraoperative air deposits and postoperative T2-weighted MRI fluid signals were mapped in relation to calculated targets. The deepest air deposit was found 4.5 ± 1.0 mm (mean ± 2 SEM) from target. The apex of the T2-hyperintense tract was found 2.8 ± 0.8 mm from target. On average, air pockets were found anterior (1.2 ± 1.1 mm, p = 0.04) and superior (2.4 ± 1.0 mm, p < 0.001) to the target; no directional bias was noted for the apex of the T2-hyperintense tract. Location and distribution of air deposits were variable and were affected by the relationship of cannula trajectory to stroke cavity. Precise stereotactic cell transplantation is a little-studied technical challenge. Reflux of cell suspension and air, and the structure of the injection tract affect delivery of cell suspensions. Intraoperative CT allows assessment of delivery and potential trajectory correction.
Sections du résumé
BACKGROUND
While multiple trials have employed stereotactic stem cell transplantation, injection techniques have received little critical attention. Precise cell delivery is critical for certain applications, particularly when targeting deep nuclei.
METHODS
Ten patients with a history of ischemic stroke underwent CT-guided stem cell transplantation. Cells were delivered along 3 tracts adjacent to the infarcted area. Intraoperative air deposits and postoperative T2-weighted MRI fluid signals were mapped in relation to calculated targets.
RESULTS
The deepest air deposit was found 4.5 ± 1.0 mm (mean ± 2 SEM) from target. The apex of the T2-hyperintense tract was found 2.8 ± 0.8 mm from target. On average, air pockets were found anterior (1.2 ± 1.1 mm, p = 0.04) and superior (2.4 ± 1.0 mm, p < 0.001) to the target; no directional bias was noted for the apex of the T2-hyperintense tract. Location and distribution of air deposits were variable and were affected by the relationship of cannula trajectory to stroke cavity.
CONCLUSIONS
Precise stereotactic cell transplantation is a little-studied technical challenge. Reflux of cell suspension and air, and the structure of the injection tract affect delivery of cell suspensions. Intraoperative CT allows assessment of delivery and potential trajectory correction.