Pacing therapy in children with isolated complete atrioventricular block: a retrospective study of pacing system survival and pacing-related complications in a national cohort.


Journal

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
ISSN: 1532-2092
Titre abrégé: Europace
Pays: England
ID NLM: 100883649

Informations de publication

Date de publication:
01 Nov 2019
Historique:
received: 14 03 2019
accepted: 30 09 2019
pubmed: 15 10 2019
medline: 26 11 2020
entrez: 15 10 2019
Statut: ppublish

Résumé

To evaluate pacing system survival and complications to pacemaker (PM) therapy in children with isolated complete atrioventricular block (CAVB). We performed a nationwide retrospective study of children diagnosed before 15 years of age with isolated CAVB and PM treatment. Between 1983 and 2012, 127 patients underwent PM-implantations at 3.2 (0-17) [median (range)] years and were followed for 11 (0.6-19) years. An endocardial or epicardial PM system was implanted in 72 and 55 patients, respectively. A total of 306 pacing leads (76% steroid-eluting) were implanted. Pacing system survival was significantly affected by age, with a higher risk of a new intervention for children aged <1 month at first implantation. Lead survival of the steroid-eluting leads at 5 and 10 years was 90 and 81%, respectively, with no difference between epicardial and endocardial systems. Complications leading to revision of the pacing system occurred in 24% of the patients. Patients aged <1 month at first PM implantation had a five-fold increased risk for a complication to occur. Dividing the cohort according to year of first procedure showed that those who had their first implantation ≥2002 had fewer complications and also lead- and pacing system survival was better in the later cohort. Pacing system survival and complications to PM therapy in young patients with isolated CAVB were significantly affected by age, with low age at PM implantation constituting a risk factor. Endocardial and epicardial pacing systems showed no significant differences in performance.

Identifiants

pubmed: 31609447
pii: 5586987
doi: 10.1093/europace/euz268
doi:

Types de publication

Journal Article Multicenter Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

1717-1724

Commentaires et corrections

Type : CommentIn
Type : CommentIn

Informations de copyright

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.

Auteurs

Håkan Eliasson (H)

Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.

Sven-Erik Sonesson (SE)

Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.

Stina Salomonsson (S)

Department of Medicine, Karolinska Institutet, Stockholm, Sweden.

Amanda Skog Andreasson (A)

Department of Medicine, Karolinska Institutet, Stockholm, Sweden.

Marie Wahren-Herlenius (M)

Department of Medicine, Karolinska Institutet, Stockholm, Sweden.

Fredrik Gadler (F)

Department of Medicine, Karolinska Institutet, Stockholm, Sweden.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH