Peel bond strength between 3D printing tray materials and elastomeric impression/adhesive systems: A laboratory study.

Additive manufacturing Bond strength Custom tray Digital light processing Elastomeric impression material Fused filament fabrication Polyether Stereolithography Vinyl polysiloxane Vinylsiloxanether

Journal

Dental materials : official publication of the Academy of Dental Materials
ISSN: 1879-0097
Titre abrégé: Dent Mater
Pays: England
ID NLM: 8508040

Informations de publication

Date de publication:
07 2020
Historique:
received: 01 08 2019
revised: 31 01 2020
accepted: 28 04 2020
pubmed: 28 5 2020
medline: 21 10 2020
entrez: 28 5 2020
Statut: ppublish

Résumé

The present study aimed to evaluate the bonding between three 3D printed custom tray materials and three elastomeric impression/adhesive systems using the peel test. Test blocks were 3D printed by three different technologies using Dental LT, FREEPRINT tray, and polylactide (PLA) tray materials. The reference test blocks were conventionally fabricated with Zeta Tray LC, a light-curing resin. The surface topographies of the four tray materials were investigated by scanning electron microscopy (SEM) analyses and roughness measurements. The peel bond strength between the four tray materials and three impression/adhesive systems, vinylsiloxanether (VSXE), vinyl polysiloxane (VPS), and polyether (PE), was measured (n=12 per group). The peeling failure modes and rupture sites were identified microscopically. The four tray materials featured different surface topographies. The peel bond strength was not significantly different with VSXE and PE, but PLA and the reference showed higher peel bond strength with VPS than the Dental LT and FREEPRINT tray (p<0.05). The rupture site of adhesive failure in all groups was partly at the adhesive-impression material interface and partly within the adhesive but never at the adhesive-tray material interface. The 3D printed tray materials can achieve satisfactory chemical compatibility with the adhesives of VSXE, VPS, and PE. Surface topographies generated by the 3D printing technologies may affect bonding. Generally, 3D printed tray materials can provide clinically adequate bond strength with the elastomeric impression/adhesive systems. PLA is recommended for bonding with VPS when severe impression removal resistance is detected.

Identifiants

pubmed: 32456949
pii: S0109-5641(20)30124-X
doi: 10.1016/j.dental.2020.04.015
pii:
doi:

Substances chimiques

Dental Cements 0
Dental Impression Materials 0

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Pagination

e241-e254

Informations de copyright

Copyright © 2020 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

Auteurs

Y Xu (Y)

University Hospital Tuebingen, Section Medical Materials Science and Technology, Osianderstr. 2-8, Tuebingen 72076, Germany; State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China; Department of Oral Prosthodontics I, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China. Electronic address: xuyichen10@126.com.

F Huettig (F)

Department of Prosthodontics at the University Clinic for Dentistry, Oral Medicine, and Maxillofacial Surgery, University Hospital Tuebingen, Osianderstr. 2-8, Tuebingen 72076, Germany.

C Schille (C)

University Hospital Tuebingen, Section Medical Materials Science and Technology, Osianderstr. 2-8, Tuebingen 72076, Germany.

E Schweizer (E)

University Hospital Tuebingen, Section Medical Materials Science and Technology, Osianderstr. 2-8, Tuebingen 72076, Germany.

J Geis-Gerstorfer (J)

University Hospital Tuebingen, Section Medical Materials Science and Technology, Osianderstr. 2-8, Tuebingen 72076, Germany.

S Spintzyk (S)

University Hospital Tuebingen, Section Medical Materials Science and Technology, Osianderstr. 2-8, Tuebingen 72076, Germany.

Articles similaires

Hemiarthroplasty in young patients.

Hazimah Mahmud, Dong Wang, Andra Topan-Rat et al.
1.00
Humans Male Hemiarthroplasty Middle Aged Aged
Silicon Dioxide Water Hot Temperature Compressive Strength X-Ray Diffraction
Nitriles Tensile Strength Materials Testing Gloves, Protective Product Packaging
Calcium Carbonate Sand Powders Construction Materials Materials Testing

Classifications MeSH