Biventricular assistance with 2 hm3 in a small chest patient: extra-pericardial implant.
Body Size
/ physiology
Cardiovascular Surgical Procedures
/ instrumentation
Extracorporeal Circulation
/ instrumentation
Female
Heart Failure
/ pathology
Heart Valve Prosthesis Implantation
/ adverse effects
Heart-Assist Devices
/ adverse effects
Humans
Middle Aged
Postoperative Complications
/ therapy
Shock, Cardiogenic
/ pathology
Thorax
/ pathology
Treatment Outcome
Bi-VAD
HeartMate 3
Left ventricular assist device
Journal
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs
ISSN: 1619-0904
Titre abrégé: J Artif Organs
Pays: Japan
ID NLM: 9815648
Informations de publication
Date de publication:
Jun 2021
Jun 2021
Historique:
received:
24
06
2020
accepted:
04
08
2020
pubmed:
18
8
2020
medline:
31
7
2021
entrez:
18
8
2020
Statut:
ppublish
Résumé
We describe the clinical course and treatment of a 53-year-old female, with small chest dimensions, referred to our institution for a primary cardiogenic shock. The patient underwent an on-pump left ventricular assist-device (VAD) implantation with the aid of immediate post-operative paracorporeal right-VAD assistance for an acute right ventricular failure. After two unsuccessful weaning attempts, she underwent extrapericardial HM 3 RVAD implantation.
Identifiants
pubmed: 32803544
doi: 10.1007/s10047-020-01200-0
pii: 10.1007/s10047-020-01200-0
doi:
Types de publication
Case Reports
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
261-264Références
Soliman O II, Akin S, Muslem R, Boersma E, Manintveld OC, Krabatsch T, Gummert JF, de By TMMH, Bogers AJJC, Zijlstra F, Mohacsi P, Caliskan K, EUROMACS Investigators. Derivation and validation of a novel right-sided heart failure model after implantation of continuous flow left ventricular assist devices: The EUROMACS (European Registry for Patients with Mechanical Circulatory Support) right-sided heart failure risk score. Circulation. 2018;137:891–906.
doi: 10.1161/CIRCULATIONAHA.117.030543
Potapov EV, Kukucka M, Falk V, Krabatsch T. Biventricular support using 2 HeartMate 3 pumps. J Heart Lung Transplan. 2016;35:1268–70.
doi: 10.1016/j.healun.2016.07.013
Carrozzini M, Bejko J, Guariento A, Rubino M, Bianco R, Tarzia V, Gregori D, Bottio T, Gerosa G. Minimally invasive implantation of continuous flow left ventricular assist devices: the evolution of surgical techniques in a single-center experience. Artif Organs. 2019;43:E41–E52.
doi: 10.1111/aor.13339
Carrozzini M, Bejko J, Gerosa G, Bottio T. Bilateral mini-thoracotomy approach for minimally invasive implantation of HeartMate 3. Artif Organs. 2019;43:593–5.
doi: 10.1111/aor.13387
Kirklin JK, Pagani FD, Kormos RL, Stevenson LW, Blume ED, Myers SL, Miller MA, Baldwin JT, Young JB, Naftel DC. Eighth annual INTERMACS report: special focus on framing the impact of adverse events. J Heart Lung Transplan. 2017;36:1080–6.
doi: 10.1016/j.healun.2017.07.005
Carrozzini M, Bejko J, Gambino A, Tarzia V, Lanera C, Gregori D, Gerosa G, Bottio T. Results of new-generation intrapericardial continuous flow left ventricular assist devices as a bridge-to-transplant. J Cardiovasc Med (Hagerstown). 2018;19:739–47.
doi: 10.2459/JCM.0000000000000721
Schulz A, Potapov E, Cho MY. Intracorporeal Biventricular Assist Device Therapy in an 8-Year-Old Child. Semin Thorac Cardiovasc Surg. 2019;31:110–1.
doi: 10.1053/j.semtcvs.2018.06.002
Mehra MR, Uriel N, Naka Y, Cleveland JCJ, Yuzefpolskaya M, Salerno CT, Walsh MN, Milano CA, Patel CB, Hutchins SW, Ransom J, Ewald GA, Itoh A, Raval NY, Silvestry SC, Cogswell R, John R, Bhimaraj A, Bruckner BA, Lowes BD, Um JY, Jeevanandam V, Sayer G, Mangi AA, Molina EJ, Sheikh F, Aaronson K, Pagani FD, Cotts WG, Tatooles AJ, Babu A, Chomsky D, Katz JN, Tessmann PB, Dean D, Krishnamoorthy A, Chuang J, Topuria I, Sood P, Goldstein DJ, MOMENTUM 3 Investigators. A fully magnetically levitated left ventricular assist device - final report. N Engl J Med. 2019;380:1618–27.
doi: 10.1056/NEJMoa1900486
O'Connor MJ, Lorts A, Davies RR, Fynn-Thompson F, Joong A, Maeda K, Mascio CE, McConnell PI, Mongé MC, Nandi D, Peng DM, Rosenthal DN, Si MS, Sutcliffe DL, VanderPluym CJ, Viegas M, Zafar F, Zinn M, Morales DLS. Early experience with the HeartMate 3 continuous-flow ventricular assist device in pediatric patients and patients with congenital heart disease: a multicenter registry analysis. J Heart Lung Transplant. 2020;39:573–9.
doi: 10.1016/j.healun.2020.02.007
Krabatsch T, Potapov E, Stepanenko A, Schweiger M, Kukucka M, Huebler M, Hennig E, Hetzer R. Biventricular circulatory support with two miniaturized implantable assist devices. Circulation. 2011;124:S179–S186186.
doi: 10.1161/CIRCULATIONAHA.110.011502
Strueber M, Meyer AL, Malehsa D, Haverich A. Successful use of the HeartWare HVAD rotary blood pump for biventricular support. J Thorac Cardiovasc Surg. 2010;140:936–7. https://doi.org/10.1016/j.jtcvs.2010.04.007 .
doi: 10.1016/j.jtcvs.2010.04.007
pubmed: 20478575