Fetal whole heart blood flow imaging using 4D cine MRI.


Journal

Nature communications
ISSN: 2041-1723
Titre abrégé: Nat Commun
Pays: England
ID NLM: 101528555

Informations de publication

Date de publication:
05 10 2020
Historique:
received: 13 09 2019
accepted: 10 09 2020
entrez: 6 10 2020
pubmed: 7 10 2020
medline: 23 10 2020
Statut: epublish

Résumé

Prenatal detection of congenital heart disease facilitates the opportunity for potentially life-saving care immediately after the baby is born. Echocardiography is routinely used for screening of morphological malformations, but functional measurements of blood flow are scarcely used in fetal echocardiography due to technical assumptions and issues of reliability. Magnetic resonance imaging (MRI) is readily used for quantification of abnormal blood flow in adult hearts, however, existing in utero approaches are compromised by spontaneous fetal motion. Here, we present and validate a novel method of MRI velocity-encoding combined with a motion-robust reconstruction framework for four-dimensional visualization and quantification of blood flow in the human fetal heart and major vessels. We demonstrate simultaneous 4D visualization of the anatomy and circulation, which we use to quantify flow rates through various major vessels. The framework introduced here could enable new clinical opportunities for assessment of the fetal cardiovascular system in both health and disease.

Identifiants

pubmed: 33020487
doi: 10.1038/s41467-020-18790-1
pii: 10.1038/s41467-020-18790-1
pmc: PMC7536221
mid: EMS96572
doi:

Banques de données

figshare
['10.6084/m9.figshare.c.4689437']

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

4992

Subventions

Organisme : Wellcome Trust
ID : 102431
Pays : United Kingdom
Organisme : Wellcome Trust
ID : 203148
Pays : United Kingdom
Organisme : Medical Research Council
ID : MR/K0006355/1
Pays : United Kingdom
Organisme : Wellcome Trust
ID : 203148/Z/16/Z
Pays : United Kingdom
Organisme : Medical Research Council
ID : MR/K006355/1
Pays : United Kingdom
Organisme : Department of Health
Pays : United Kingdom

Commentaires et corrections

Type : ErratumIn

Références

Kenny, J. F. et al. Changes in intracardiac blood flow velocities and right and left ventricular stroke volumes with gestational age in the normal human fetus: a prospective Doppler echocardiographic study. Circulation 74, 1208–1216 (1986).
pubmed: 3779910 pmcid: 3779910
Hecher, K., Campbell, S., Doyle, P., Harrington, K. & Nicolaides, K. Assessment of fetal compromise by Doppler ultrasound investigation of the fetal circulation: arterial, intracardiac, and venous blood flow velocity studies. Circulation 91, 129–138 (1995).
pubmed: 7805194 pmcid: 7805194
Arabin, B. Doppler Blood Flow Measurement In Uteroplacental And Fetal Vessels: Pathophysiological And Clinical Significance. 1–148, https://doi.org/10.1007/978-3-642-74991-9 (Springer Science & Business Media, 2012).
Gill, R. W. Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med. Biol. 11, 625–641 (1985).
pubmed: 2931884 pmcid: 2931884
Hoskins, P. Measurement of arterial blood flow by Doppler ultrasound. Clin. Phys. Physiol. Meas. 11, 1 (1990).
pubmed: 2182271 pmcid: 2182271
Burns, P. Measuring volume flow with Doppler ultrasound—an old nut. Ultrasound Obstet. Gynecol. 2, 238–241 (1992).
pubmed: 12796946 pmcid: 12796946
Hoyt, K., Hester, F. A., Bell, R. L., Lockhart, M. E. & Robbin, M. L. Accuracy of volumetric flow rate measurements: an in vitro study using modern ultrasound scanners. J. Ultrasound Med. 28, 1511–1518 (2009).
pubmed: 19854966 pmcid: 19854966
Blanco, P. Volumetric blood flow measurement using Doppler ultrasound: concerns about the technique. J. Ultrasound 18, 201–204 (2015).
pubmed: 26191112 pmcid: 26191112
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M. & Wieben, O. 4D flow MRI. J. Magn. Reson. Imaging 36, 1015–1036 (2012).
pubmed: 23090914 pmcid: 23090914
Lotz, J., Meier, C., Leppert, A. & Galanski, M. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 22, 651–671 (2002).
pubmed: 12006694 pmcid: 12006694
Nayak, K. S. et al. Cardiovascular magnetic resonance phase contrast imaging. J. Cardiovasc. Magn. Reson. 17, 71 (2015).
pubmed: 26254979 pmcid: 26254979
Markl, M., Kilner, P. J. & Ebbers, T. Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J. Cardiovasc. Magn. Reson. 13, 1–22 (2011).
Lawley, C. M. et al. 4D flow magnetic resonance imaging: role in pediatric congenital heart disease. Asian Cardiovasc. Thorac. Ann. 26, 28–37 (2018).
pubmed: 28185475 pmcid: 28185475
Powell, A., Maier, S., Chung, T. & Geva, T. Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: in vitro and in vivo validation. Pediatr. Cardiol. 21, 104–110 (2000).
pubmed: 10754076 pmcid: 10754076
Hsiao, A. et al. Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI. Pediatr. Radiol. 41, 711–720 (2011).
pubmed: 21221566 pmcid: 21221566
Broadhouse, K. M. et al. Assessment of PDA shunt and systemic blood flow in newborns using cardiac MRI. NMR Biomed. 26, 1135–1141 (2013).
pubmed: 23412748 pmcid: 23412748
Broadhouse, K. M. et al. 4D phase contrast MRI in the preterm infant: visualisation of patent ductus arteriosus. Arch. Dis. Child. Fetal Neonatal Ed. 100, F164–F164 (2015).
pubmed: 24907162 pmcid: 24907162
Jansz, M. S. et al. Metric optimized gating for fetal cardiac MRI. Magn. Reson. Med. 64, 1304–1314 (2010).
pubmed: 20632406 pmcid: 20632406
Goolaub, D. S. et al. Multidimensional fetal flow imaging with cardiovascular magnetic resonance: a feasibility study. J. Cardiovasc. Magn. Reson. 20, 77 (2018).
pubmed: 30486832 pmcid: 30486832
Schoennagel, B. et al. Fetal dynamic phase-contrast MR angiography using ultrasound gating and comparison with Doppler ultrasound measurements. Eur. Radiol. 29, 4169–4176 (2019).
pubmed: 30617486 pmcid: 30617486
Salehi, D. et al. Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating: validation against metric optimized gating. J. Cardiovasc. Magn. Reson. 21, 74 (2019).
pubmed: 31783877 pmcid: 31783877
Schrauben, E. M. et al. Fetal hemodynamics and cardiac streaming assessed by 4D flow cardiovascular magnetic resonance in fetal sheep. J. Cardiovasc. Magn. Reson. 21, 8 (2019).
pubmed: 30661506 pmcid: 30661506
Macdonald, J. A. et al. Uteroplacental and fetal 4D flow MRI in the pregnant rhesus macaque. J. Magn. Reson. Imaging 49, 534–545 (2019).
pubmed: 30102431 pmcid: 30102431
Kording, F. et al. Fetal cardiac 4D phase-contrast MRI using Doppler ultrasound gating to visualize fetal hemodynamics in utero: preliminary results. Proc. Intl. Soc. Mag. Reson. Med. 27, 4055 (2019).
Kording, F. et al. Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating. J. Cardiovasc. Magn. Reson. 20, 17 (2018).
pubmed: 29530064 pmcid: 29530064
Yamamura, J. et al. Cardiac MRI of the fetal heart using a novel triggering method: initial results in an animal model. J. Magn. Reson. Imaging 35, 1071–1076 (2012).
pubmed: 22246623 pmcid: 22246623
Lloyd, D. F. et al. Three-dimensional visualisation of the fetal heart using prenatal MRI with motion-corrected slice-volume registration: a prospective, single-centre cohort study. Lancet 393, 1619–1627 (2019).
pubmed: 30910324 pmcid: 30910324
Kuklisova-Murgasova, M., Quaghebeur, G., Rutherford, M. A., Hajnal, J. V. & Schnabel, J. A. Reconstruction of fetal brain MRI with intensity matching and complete outlier removal. Med. Image Anal. 16, 1550–1564 (2012).
pubmed: 22939612 pmcid: 22939612
Gholipour, A., Estroff, J. A. & Warfield, S. K. Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI. IEEE Trans. Med. Imaging 29, 1739–1758 (2010).
pubmed: 20529730 pmcid: 20529730
Jiang, S. et al. MRI of moving subjects using multislice snapshot images with volume reconstruction (SVR): application to fetal, neonatal, and adult brain studies. IEEE Trans. Med. imaging 26, 967–980 (2007).
pubmed: 17649910 pmcid: 17649910
Rousseau, F., Kim, K., Studholme, C., Koob, M., Dietemann, J.-L. On super-resolution for fetal brain MRI. Med. Image Comput. Comput. Assist. Interv. 13, 355–362 (2010).
van Amerom, J. F. et al. Fetal cardiac cine imaging using highly accelerated dynamic MRI with retrospective motion correction and outlier rejection. Magn. Reson. Med. 79, 327–338 (2018).
pubmed: 28370252 pmcid: 28370252
van Amerom, J. F. et al. Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI. Magn. Reson. Med. 82, 1055–1072 (2019).
pubmed: 31081250 pmcid: 31081250
Tsao, J., Boesiger, P. & Pruessmann, K. P. k‐t BLAST and k‐t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn. Reson. Med. 50, 1031–1042 (2003).
pubmed: 14587014 pmcid: 14587014
Tsao, J., Kozerke, S., Boesiger, P. & Pruessmann, K. P. Optimizing spatiotemporal sampling for k‐t BLAST and k‐t SENSE: application to high‐resolution real‐time cardiac steady‐state free precession. Magn. Reson. Med. 53, 1372–1382 (2005).
pubmed: 15906282 pmcid: 15906282
Stankovic, Z., Allen, B. D., Garcia, J., Jarvis, K. B. & Markl, M. 4D flow imaging with MRI. Cardiovasc. Diagn. Ther. 4, 173 (2014).
pubmed: 24834414 pmcid: 24834414
Dyverfeldt, P. et al. 4D flow cardiovascular magnetic resonance consensus statement. J. Cardiovasc. Magn. Reson. 17, 72 (2015).
pubmed: 26257141 pmcid: 26257141
Markl, M., Alley, M. & Pelc, N. Balanced phase‐contrast steady‐state free precession (PC‐SSFP): a novel technique for velocity encoding by gradient inversion. Magn. Reson. Med. 49, 945–952 (2003).
pubmed: 12704778 pmcid: 12704778
Nielsen, J. F. & Nayak, K. S. Referenceless phase velocity mapping using balanced SSFP. Magn. Reson. Med. 61, 1096–1102 (2009).
Santini, F., Wetzel, S. G., Bock, J., Markl, M. & Scheffler, K. Time‐resolved three‐dimensional (3D) phase‐contrast (PC) balanced steady‐state free precession (bSSFP). Magn. Reson. Med. 62, 966–974 (2009).
pubmed: 19585606 pmcid: 19585606
Hargreaves, B. Rapid gradient‐echo imaging. J. Magn. Reson. Imaging 36, 1300–1313 (2012).
pubmed: 23097185 pmcid: 23097185
Bieri, O. & Scheffler, K. Fundamentals of balanced steady state free precession MRI. J. Magn. Reson. Imaging 38, 2–11 (2013).
pubmed: 23633246 pmcid: 23633246
Kiserud, T. & Acharya, G. The fetal circulation. Prenat. Diagnosis 24, 1049–1059 (2004).
Prsa, M. et al. Reference ranges of blood flow in the major vessels of the normal human fetal circulation at term by phase-contrast magnetic resonance imaging. Circulation 7, 663–670 (2014).
pubmed: 24874055 pmcid: 24874055
Pelc, N. J. et al. Quantitative magnetic resonance flow imaging. Magn. Reson. Q. 10, 125–147 (1994).
pubmed: 7811608 pmcid: 7811608
Bernstein, M. A. et al. Concomitant gradient terms in phase contrast MR: analysis and correction. Magn. Reson. Med. 39, 300–308 (1998).
pubmed: 9469714 pmcid: 9469714
Markl, M. et al. Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions. Magn. Reson. Med. 50, 791–801 (2003).
pubmed: 14523966 pmcid: 14523966
Bollache, E. et al. k‐t accelerated aortic 4D flow MRI in under two minutes: feasibility and impact of resolution, k‐space sampling patterns, and respiratory navigator gating on hemodynamic measurements. Magn. Reson. Med. 79, 195–207 (2018).
pubmed: 28266062 pmcid: 28266062
Giese, D., Schaeffter, T. & Kozerke, S. Highly undersampled phase‐contrast flow measurements using compartment‐based k–t principal component analysis. Magn. Reson. Med. 69, 434–443 (2013).
pubmed: 22528878 pmcid: 22528878
Schnell, S. et al. k‐t GRAPPA accelerated four‐dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress. Magn. Reson. Med. 72, 522–533 (2014).
pubmed: 24006309 pmcid: 24006309
Vigneswaran, T. V. et al. Reference ranges for the size of the fetal cardiac outflow tracts from 13 to 36 weeks gestation: a single-center study of over 7000 cases. Circulation 11, e007575 (2018).
pubmed: 30006353 pmcid: 30006353
Deprez, M. et al. Higher order spherical harmonics reconstruction of fetal diffusion MRI with intensity correction. IEEE Trans. Med. Imaging 39, 1104–1113 (2020).
Nayak, K. S. Response to Letter to the Editor: “Nomenclature for real‐time magnetic resonance imaging”. Magn. Reson. Med. 82, 525–526 (2019).
pubmed: 31025418 pmcid: 31025418
Lorenz, R. et al. Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC‐MRI data. Magn. Reson. Med. 72, 33–40 (2014).
pubmed: 24006013 pmcid: 24006013
Hand, J., Li, Y. & Hajnal, J. Numerical study of RF exposure and the resulting temperature rise in the foetus during a magnetic resonance procedure. Phys. Med. Biol. 55, 913 (2010).
pubmed: 20090188 pmcid: 20090188
Commission I. E. Medical electrical equipment—Part 2–33: particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis. IEC 60601-2-33 Ed 3.0 (2010).
Glover, P. et al. An assessment of the intrauterine sound intensity level during obstetric echo-planar magnetic resonance imaging. Br. J. Radiol. 68, 1090–1094 (1995).
pubmed: 7496710 pmcid: 7496710
Tournier, J.-D. et al. MRtrix3: A fast, flexible and open software framework for medical image processing and visualisation. NeuroImage 202, 116137 (2019).
pubmed: 31473352 pmcid: 31473352
Ahrens, J., Geveci, B., Law, C. Paraview: an end-user tool for large data visualization. Vis. Handb. 717, https://www.paraview.org/publications/ (2005).
Baker, P. N. et al. Fetal weight estimation by echo-planar magnetic resonance imaging. Lancet 343, 644–645 (1994).
pubmed: 7906814 pmcid: 7906814

Auteurs

Thomas A Roberts (TA)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK. t.roberts@kcl.ac.uk.

Joshua F P van Amerom (JFP)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Alena Uus (A)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

David F A Lloyd (DFA)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.
Department of Congenital Heart Disease, Evelina Children's Hospital, London, SE1 7EH, UK.

Milou P M van Poppel (MPM)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.
Department of Congenital Heart Disease, Evelina Children's Hospital, London, SE1 7EH, UK.

Anthony N Price (AN)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Jacques-Donald Tournier (JD)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Chloe A Mohanadass (CA)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Laurence H Jackson (LH)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Shaihan J Malik (SJ)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Kuberan Pushparajah (K)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.
Department of Congenital Heart Disease, Evelina Children's Hospital, London, SE1 7EH, UK.

Mary A Rutherford (MA)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.
Centre for the Developing Brain, King's College London, London, SE1 7EH, UK.

Reza Razavi (R)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.
Department of Congenital Heart Disease, Evelina Children's Hospital, London, SE1 7EH, UK.

Maria Deprez (M)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Joseph V Hajnal (JV)

School of Biomedical Engineering & Imaging Sciences, King's College London, London, SE1 7EH, UK.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH