Reduction of CT artifacts from cardiac implantable electronic devices using a combination of virtual monoenergetic images and post-processing algorithms.


Journal

European radiology
ISSN: 1432-1084
Titre abrégé: Eur Radiol
Pays: Germany
ID NLM: 9114774

Informations de publication

Date de publication:
Sep 2021
Historique:
received: 19 10 2020
accepted: 04 02 2021
revised: 16 12 2020
pubmed: 26 2 2021
medline: 25 8 2021
entrez: 25 2 2021
Statut: ppublish

Résumé

To evaluate the reduction of artifacts from cardiac implantable electronic devices (CIEDs) by virtual monoenergetic images (VMI), metal artifact reduction (MAR) algorithms, and their combination (VMI In this retrospective study, we included 34 patients (mean age 74.6 ± 8.6 years), who underwent a SDCT of the chest and had a CIED in place. CI, MAR, VMI, and VMI Compared to CI, MAR and VMI The combination of VMI and MAR as well as MAR as a standalone approach provides effective reduction of artifacts from CIEDs. Still, higher keV values should be applied with caution due to a loss of soft tissue and vessel contrast along the leads. • The combination of VMI and MAR as well as MAR as a standalone approach enables effective reduction of artifacts from CIEDs. • Higher keV values of both VMI and VMI

Identifiants

pubmed: 33630164
doi: 10.1007/s00330-021-07746-8
pii: 10.1007/s00330-021-07746-8
pmc: PMC8379133
doi:

Substances chimiques

Metals 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

7151-7161

Informations de copyright

© 2021. The Author(s).

Références

Wong JA, Devereaux PJ (2019) Cardiac device implantation complications: a gap in the quality of care? Ann Intern Med 171:368–369
doi: 10.7326/M19-1895
Aguilera AL, Volokhina YV, Fisher KL (2011) Radiography of cardiac conduction devices: a comprehensive review. Radiographics 31:1669–1682
doi: 10.1148/rg.316115529
Aissa J, Boos J, Sawicki LM et al (2017) Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms. Br J Radiol 90. https://doi.org/10.1259/bjr.20160778
Lewis RK, Ehieli WL, Hegland DD et al (2020) Preprocedural computed tomography before cardiac implanted electronic device lead extraction: indication, technique, and approach to interpretation. J Cardiovasc Electrophysiol 31:723–732
doi: 10.1111/jce.14353
Mak GS, Truong QA (2012) Cardiac CT: imaging of and through cardiac devices. Curr Cardiovasc Imaging Rep 5:328–336
doi: 10.1007/s12410-012-9150-8
Fayad LM, Patra A, Fishman EK (2009) Value of 3D CT in defining skeletal complications of orthopedic hardware in the postoperative patient. AJR Am J Roentgenol 193:1155–1163
Lee M-J, Kim S, Lee S-A et al (2007) Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. Radiographics 27:791–803
doi: 10.1148/rg.273065087
Mori I, Machida Y, Osanai M, Iinuma K (2013) Photon starvation artifacts of X-ray CT: their true cause and a solution. Radiol Phys Technol 6:130–141
doi: 10.1007/s12194-012-0179-9
Boas FE, Fleischmann D (2012) CT artifacts: causes and reduction techniques. Imaging Med 4:229–240
doi: 10.2217/iim.12.13
Lennartz S, Große Hokamp N, Abdullayev N et al (2019) Diagnostic value of spectral reconstructions in detecting incidental skeletal muscle metastases in CT staging examinations. Cancer Imaging 19:50
doi: 10.1186/s40644-019-0235-3
Kalisz K, Buethe J, Saboo SS, Abbara S, Halliburton S, Rajiah P (2016) Artifacts at cardiac CT: physics and solutions. Radiographics 36:2064–2083
Tatsugami F, Higaki T, Sakane H et al (2016) Coronary CT angiography in patients with implanted cardiac devices: initial experience with the metal artefact reduction technique. Br J Radiol 89:20160493
doi: 10.1259/bjr.20160493
Laukamp KR, Zopfs D, Lennartz S et al (2019) Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts. Eur Radiol 29:4228–4238
doi: 10.1007/s00330-018-5928-7
Aissa J, Thomas C, Sawicki LM et al (2017) Iterative metal artefact reduction in CT: can dedicated algorithms improve image quality after spinal instrumentation? Clin Radiol 72:428.e7–428.e12. https://doi.org/10.1016/j.crad.2016.12.006
doi: 10.1016/j.crad.2016.12.006
Kikuchi N, Yanagawa M, Enchi Y et al (2020) The effect of the reconstruction algorithm for the pulmonary nodule detection under the metal artifact caused by a pacemaker. Medicine (Baltimore) 99:e20579
doi: 10.1097/MD.0000000000020579
Lossau (née Elss) T, Nickisch H, Wissel T, Morlock M, Grass M (2020) Learning metal artifact reduction in cardiac CT images with moving pacemakers. Med Image Anal 61. https://doi.org/10.1016/j.media.2020.101655
Van Hedent S, Kessner R, Große Hokamp N, Baran TZ, Kosmas C, Gupta A (2019) Metal artifact reduction in routine chest and abdominal examinations using virtual monoenergetic images from spectral detector computed tomography. J Comput Assist Tomogr 43:713–717
Große Hokamp N, Laukamp KR, Lennartz S et al (2018) Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT. Eur J Radiol 104:136–142
doi: 10.1016/j.ejrad.2018.04.018
McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637–653
doi: 10.1148/radiol.2015142631
Große Hokamp N, Neuhaus V, Abdullayev N et al (2017) Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms. Skeletal Radiol 47:195–201
doi: 10.1007/s00256-017-2776-5
Zopfs D, Lennartz S, Pennig L et al (2020) Virtual monoenergetic images and post-processing algorithms effectively reduce CT artifacts from intracranial aneurysm treatment. Sci Rep 10. https://doi.org/10.1038/s41598-020-63574-8
(2012) Philips CT Clinical Science PHU. Metal Artifact Reduction for Orthopedic Implants (O-MAR). Accessed December 2020. Availabel at: http://clinical.netforum.healthcare.philips.com/us_en/Explore/White-Papers/CT/Metal-Artifact-Reduction-for-O
Cicchetti DV (1994) Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology. Psychol Assess 6:284–290
doi: 10.1037/1040-3590.6.4.284
Wellenberg RHH, Hakvoort ET, Slump CH, Boomsma MF, Maas M, Streekstra GJ (2018) Metal artifact reduction techniques in musculoskeletal CT-imaging. Eur J Radiol 107:60–69
Große Hokamp N, Hellerbach A, Gierich A et al (2018) Reduction of artifacts caused by deep brain stimulating electrodes in cranial computed tomography imaging by means of virtual monoenergetic images, metal artifact reduction algorithms, and their combination. Invest Radiol 53:424–431
doi: 10.1097/RLI.0000000000000460
Laukamp KR, Gupta A, Große Hokamp N et al (2019) Role of spectral-detector CT in reduction of artifacts from contrast media in axillary and subclavian veins: single institution study in 50 patients. Acta Radiol 028418511986890
Pan YN, Chen G, Li AJ et al (2019) Reduction of metallic artifacts of the post-treatment intracranial aneurysms: effects of single energy metal artifact reduction algorithm. Clin Neuroradiol. https://doi.org/10.1007/s00062-017-0644-2
Fitsiori A, Martin SP, Juillet De Saint Lager A et al (2019) Iterative algorithms applied to treated intracranial aneurysms. Clin Neuroradiol 29:741–749
doi: 10.1007/s00062-018-0701-5
Dunet V, Bernasconi M, Hajdu SD, Meuli RA, Daniel RT, Zerlauth JB (2017) Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping. Neuroradiology 59:845–852
Pan Y-N, Chen G, Li A-J et al (2017) Reduction of metallic artifacts of the post-treatment intracranial aneurysms: effects of single energy metal artifact reduction algorithm. Clin Neuroradiol 1–8
Sunwoo L, Park S-W, Rhim JH et al (2018) Metal artifact reduction for orthopedic implants: brain CT angiography in patients with intracranial metallic implants. J Korean Med Sci 33:e158
doi: 10.3346/jkms.2018.33.e158
Laukamp KR, Zopfs D, Wagner A et al (2019) CT artifacts from port systems: virtual monoenergetic reconstructions from spectral-detector CT reduce artifacts and improve depiction of surrounding tissue. Eur J Radiol 121:108733
doi: 10.1016/j.ejrad.2019.108733
Lennartz S, Laukamp KR, Neuhaus V et al (2018) Dual-layer detector CT of the head: initial experience in visualization of intracranial hemorrhage and hypodense brain lesions using virtual monoenergetic images. Eur J Radiol 108:177–183
doi: 10.1016/j.ejrad.2018.09.010
Gupta A, Obmann VC, Jordan M et al (2021) CT artifacts after contrast media injection in chest imaging: evaluation of post-processing algorithms, virtual monoenergetic images and their combination for artifact reduction. Quant Imaging Med Surg 11:226–239
doi: 10.21037/qims-20-435
Huang JY, Kerns JR, Nute JL et al (2015) An evaluation of three commercially available metal artifact reduction methods for CT imaging. Phys Med Biol 60:1047–1067
doi: 10.1088/0031-9155/60/3/1047
Kidoh M, Nakaura T, Nakamura S et al (2014) Reduction of dental metallic artefacts in CT: value of a newly developed algorithm for metal artefact reduction (O-MAR). Clin Radiol 69:11–16
doi: 10.1016/j.crad.2013.08.008
Bisschop R, Boomsma M, Van Raay JJA, Tiebosch ATMG, Maas M, Gerritsma CLE (2013) High prevalence of pseudotumors in patients with a Birmingham hip resurfacing prosthesis. J Bone Joint Surg Am 95:1554–1560
Mangold S, Gatidis S, Luz O et al (2014) Single-source dual-energy computed tomography: use of monoenergetic extrapolation for a reduction of metal artifacts. Invest Radiol 49:788–793
doi: 10.1097/RLI.0000000000000083

Auteurs

Lenhard Pennig (L)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany. lenhard.pennig@uk-koeln.de.

David Zopfs (D)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Roman Gertz (R)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Johannes Bremm (J)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Charlotte Zaeske (C)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Nils Große Hokamp (N)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Erkan Celik (E)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Lukas Goertz (L)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Marcel Langenbach (M)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Thorsten Persigehl (T)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Amit Gupta (A)

Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
Department of Radiology, Case Western Reserve University, Cleveland, OH, USA.

Jan Borggrefe (J)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.

Simon Lennartz (S)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Else Kröner Forschungskolleg Clonal Evolution in Cancer, University Hospital Cologne, Cologne, Germany.

Kai Roman Laukamp (KR)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
Department of Radiology, Case Western Reserve University, Cleveland, OH, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH