Early and midterm results from a postmarket observational study of Zenith t-Branch thoracoabdominal endovascular graft.
Aged
Aortic Dissection
/ diagnostic imaging
Aortic Aneurysm, Thoracic
/ diagnostic imaging
Aortic Rupture
/ diagnostic imaging
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation
/ adverse effects
Endoleak
/ etiology
Endovascular Procedures
/ adverse effects
Female
Germany
Humans
Male
Middle Aged
Product Surveillance, Postmarketing
Prospective Studies
Prosthesis Design
Prosthesis Failure
Retrospective Studies
Risk Assessment
Risk Factors
Stents
Sweden
Time Factors
Treatment Outcome
Vascular Patency
Aortic dissection
Endovascular techniques
Ruptured aneurysm
Thoracoabdominal aortic aneurysm
Journal
Journal of vascular surgery
ISSN: 1097-6809
Titre abrégé: J Vasc Surg
Pays: United States
ID NLM: 8407742
Informations de publication
Date de publication:
10 2021
10 2021
Historique:
received:
17
08
2020
accepted:
29
01
2021
pubmed:
9
3
2021
medline:
22
12
2021
entrez:
8
3
2021
Statut:
ppublish
Résumé
We have reported the short-term outcomes regarding the safety of the off-the-shelf Zenith t-Branch multibranched thoracoabdominal stent-graft (William Cook Europe ApS, Bjaeverskov, Denmark) in a postmarket, multicenter study. Patients who had been treated with the t-Branch device from September 2012 to November 2017 at three European centers were either prospectively or retrospectively enrolled in the present study. Device implantation and postprocedural follow-up were performed according to the standard of care at each center. The primary objectives of the present study were to assess the procedure-related mortality and morbidity at 30 days and 1 year and to assess the presence of endoleaks, device integrity, and stent-graft and branch vessel patency. A total of 80 patients were included in the present study (mean age, 71.0 ± 7.4 years; 70.0% male). Most (n = 77) had been treated for thoracoabdominal aortic aneurysms (TAAAs) and the rest for dissection (n = 3). Most TAAAs were stable (72.7%; 56 of 77). The remaining TAAAs were symptomatic (7.8%; 6 of 77) or had a contained rupture (19.5%; 15 of 77). The t-Branch device was successfully deployed in 79 patients. In one patient, the delivery system of the device could not be advanced through the iliac artery. Within 30 days, one patient had died (1.3%). At 1 year, seven patients had died (8.8%), and no aortic rupture or conversion to open surgery had been reported. The 30-day neurologic events included stroke in three patients (3.8%), paraplegia in one (1.3%), and paraparesis in six patients (7.5%). Secondary interventions were required in nine patients (11.3%) during follow-up. Postoperative endoleaks were observed in 37 of 72 patients (51.4%), including type II endoleak in 30, type Ia in 4, and type III endoleak in 6 patients. At 1 year, endoleaks had been reported in 20 patients (16 with type II and 4 with type III). The t-Branch main body graft patency was 100% throughout the 1-year follow-up period. At 30 days after the procedure, all celiac and superior mesenteric artery branches were patent and one left renal and one right renal branch were occluded. At 1 year, occlusion had developed in three bridging stent-grafts for the celiac artery, one for the left renal artery, and two for the right renal artery. The t-Branch device appears safe, with good 30-day and 1-year mortality and morbidity in the present study, including both stable and symptomatic cases.
Identifiants
pubmed: 33684474
pii: S0741-5214(21)00323-2
doi: 10.1016/j.jvs.2021.01.070
pii:
doi:
Banques de données
ClinicalTrials.gov
['NCT02104089']
Types de publication
Journal Article
Multicenter Study
Observational Study
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1081-1089.e3Informations de copyright
Copyright © 2021 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.