Comparison of the Spectral Features of the Frontal Electroencephalogram in Patients Receiving Xenon and Sevoflurane General Anesthesia.


Journal

Anesthesia and analgesia
ISSN: 1526-7598
Titre abrégé: Anesth Analg
Pays: United States
ID NLM: 1310650

Informations de publication

Date de publication:
01 11 2021
Historique:
pubmed: 4 6 2021
medline: 23 11 2021
entrez: 3 6 2021
Statut: ppublish

Résumé

Depth-of-anesthesia monitoring is often utilized for patients receiving xenon anesthesia. Processed electroencephalogram (EEG) depth-of-anesthesia monitoring relies to a significant extent on frequency domain analysis of the frontal EEG, and there is evidence that the spectral features observed under anesthesia vary significantly between anesthetic agents. The spectral features of the EEG during xenon anesthesia for a surgical procedure have not previously been described. Twenty-four participants scheduled for general anesthesia for lithotripsy were randomized to receive either xenon anesthesia or sevoflurane anesthesia. Frontal EEG recordings were obtained from each participant via the Brain Anesthesia Response Monitor (BARM). Twenty-two EEG recordings were suitable for analysis: 11 in participants who received sevoflurane and 11 in participants who received xenon. Spectrograms for the duration of the anesthetic episode were produced for each participant. Group-level spectral analysis was calculated for two 30-second EEG epochs: one recorded at awake baseline and the other during maintenance anesthesia. A linear mixed-effects model was utilized to compare the changes in 5 frequency bands from baseline to maintenance between the 2 groups. The spectrograms of sevoflurane participants illustrate an increase in frontal delta (0.5-4 Hz), theta (4-8 Hz), and alpha (8-13 Hz) band power during maintenance anesthesia. In contrast, spectrograms of the xenon participants did not illustrate an increase in alpha power. The results of the linear mixed-effects model indicate that both agents were associated with a significant increase in delta power from baseline to maintenance. There was no significant difference in the magnitude of this increase observed between the agents. In contrast, sevoflurane anesthesia was associated with significantly greater absolute power in the theta, alpha, and beta (13-30 Hz) bands when compared to xenon. In terms of relative power, xenon was associated with a significant increase in delta power compared to sevoflurane, while sevoflurane was associated with greater increases in relative theta, alpha, and beta power. Both xenon anesthesia and sevoflurane anesthesia were associated with significant increases in delta power. Sevoflurane anesthesia was also associated with increases in theta, alpha, and beta power, while xenon anesthesia was associated with greater consolidation of power in the delta band. Xenon anesthesia and sevoflurane anesthesia are associated with distinct spectral features. These findings suggest that appropriate depth-of-anesthesia monitoring may require the development of agent-specific spectral measures of unconsciousness.

Sections du résumé

BACKGROUND
Depth-of-anesthesia monitoring is often utilized for patients receiving xenon anesthesia. Processed electroencephalogram (EEG) depth-of-anesthesia monitoring relies to a significant extent on frequency domain analysis of the frontal EEG, and there is evidence that the spectral features observed under anesthesia vary significantly between anesthetic agents. The spectral features of the EEG during xenon anesthesia for a surgical procedure have not previously been described.
METHODS
Twenty-four participants scheduled for general anesthesia for lithotripsy were randomized to receive either xenon anesthesia or sevoflurane anesthesia. Frontal EEG recordings were obtained from each participant via the Brain Anesthesia Response Monitor (BARM). Twenty-two EEG recordings were suitable for analysis: 11 in participants who received sevoflurane and 11 in participants who received xenon. Spectrograms for the duration of the anesthetic episode were produced for each participant. Group-level spectral analysis was calculated for two 30-second EEG epochs: one recorded at awake baseline and the other during maintenance anesthesia. A linear mixed-effects model was utilized to compare the changes in 5 frequency bands from baseline to maintenance between the 2 groups.
RESULTS
The spectrograms of sevoflurane participants illustrate an increase in frontal delta (0.5-4 Hz), theta (4-8 Hz), and alpha (8-13 Hz) band power during maintenance anesthesia. In contrast, spectrograms of the xenon participants did not illustrate an increase in alpha power. The results of the linear mixed-effects model indicate that both agents were associated with a significant increase in delta power from baseline to maintenance. There was no significant difference in the magnitude of this increase observed between the agents. In contrast, sevoflurane anesthesia was associated with significantly greater absolute power in the theta, alpha, and beta (13-30 Hz) bands when compared to xenon. In terms of relative power, xenon was associated with a significant increase in delta power compared to sevoflurane, while sevoflurane was associated with greater increases in relative theta, alpha, and beta power.
CONCLUSIONS
Both xenon anesthesia and sevoflurane anesthesia were associated with significant increases in delta power. Sevoflurane anesthesia was also associated with increases in theta, alpha, and beta power, while xenon anesthesia was associated with greater consolidation of power in the delta band. Xenon anesthesia and sevoflurane anesthesia are associated with distinct spectral features. These findings suggest that appropriate depth-of-anesthesia monitoring may require the development of agent-specific spectral measures of unconsciousness.

Identifiants

pubmed: 34081045
doi: 10.1213/ANE.0000000000005608
pii: 00000539-202111000-00026
doi:

Substances chimiques

Anesthetics, Inhalation 0
Sevoflurane 38LVP0K73A
Xenon 3H3U766W84

Types de publication

Comparative Study Journal Article Randomized Controlled Trial Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

1269-1279

Informations de copyright

Copyright © 2021 International Anesthesia Research Society.

Déclaration de conflit d'intérêts

Conflicts of Interest: See Disclosures at the end of the article.

Références

Fahy BG, Chau DF. The technology of processed electroencephalogram monitoring devices for assessment of depth of anesthesia. Anesth Analg. 2018;126:111–117.
Purdon PL, Sampson A, Pavone KJ, Brown EN. Clinical electroencephalography for anesthesiologists: part I: background and basic signatures. Anesthesiology. 2015;123:937–960.
Hirota K. Special cases: ketamine, nitrous oxide and xenon. Best Pract Res Clin Anaesthesiol. 2006;20:69–79.
Hans P, Dewandre P-Y, Brichant JF, Bonhomme V. Comparative effects of ketamine on bispectral index and spectral entropy of the electroencephalogram under sevoflurane anesthesia. Br J Anesth. 2004;94:336–340.
Maze M, Laitio T. Neuroprotective properties of xenon. Mol Neurobiol. 2020;57:118–124.
Goto T, Nakata Y, Saito H, et al. Bispectral analysis of the electroencephalogram does not predict responsiveness to verbal command in patients emerging from xenon anesthesia. Br J Anesth. 2000;85:359–363.
Fahlenkamp AV, Peters D, Biener IA, et al. Evaluation of bispectral index and auditory evoked potentials for hypnotic depth monitoring during balanced xenon anesthesia compared with sevoflurane. Br J Anesth. 2010;105:334–341.
Stoppe C, Peters D, Fahlenkamp AV, et al. aepEX monitor for the measurement of hypnotic depth in patients undergoing balanced xenon anesthesia. Br J Anesth. 2012;108:80–88.
Fahlenkamp AV, Krebber F, Rex S, et al. Bispectral index monitoring during balanced xenon or sevoflurane anesthesia in elderly patients. Eur J Anesthesiol. 2010;27:906–911.
Laitio RM, Kaskinoro K, Särkelä MO, et al. Bispectral index, entropy, and quantitative electroencephalogram during single-agent xenon anesthesia. Anesthesiology. 2008;108:63–70.
Pelentritou A, Kuhlmann L, Cormack J, et al. Source-level cortical power changes for xenon and nitrous oxide-induced reductions in consciousness in healthy male volunteers. Anesthesiology. 2020;132:1017–1033.
Colombo MA, Napolitani M, Boly M, et al. The spectral exponent of the resting EEG indexes the presence of consciousness during unresponsiveness induced by propofol, xenon, and ketamine. Neuroimage. 2019;189:631–644.
Sarasso S, Boly M, Napolitani M, et al. Consciousness and complexity during unresponsiveness induced by propofol, xenon, and ketamine. Curr Biol. 2015;25:3099–3105.
Law LS, Lo EA, Gan TJ. Xenon anesthesia: a systematic review and meta-analysis of randomized controlled trials. Anesth Analg. 2016;122:678–697.
Nakata Y, Goto T, Ishiguro Y, et al. Minimum alveolar concentration (MAC) of xenon with sevoflurane in humans. Anesthesiology. 2001;94:611–614.
Brice DD, Hetherington RR, Utting JE. A simple study of awareness and dreaming during anesthesia. Br J Anesth. 1970;42:535–542.
The Electrode Position Nomenclature C. Guideline thirteen: guidelines for standard electrode position nomenclature. J Clin Neurophysiol. 1994;11:111–113.
Bokil H, Andrews P, Kulkarni JE, Mehta S, Mitra PP. Chronux: a platform for analyzing neural signals. J Neurosci Methods. 2010;192:146–151.
Schober P, Vetter TR. Repeated measures designs and analysis of longitudinal data: if at first you do not succeed-try, try again. Anesth Analg. 2018;127:569–575.
Avramov MN, Mori K. Nitrous oxide antagonizes CNS stimulation by laudanosine in mice. Br J Anaesth. 1990;65:704–707.
Hagihira S, Takashina M, Mori T, Mashimo T. The impact of nitrous oxide on electroencephalographic bicoherence during isoflurane anesthesia. Anesth Analg. 2012;115:572–577.
Pavone KJ, Akeju O, Sampson AL, Ling K, Purdon PL, Brown EN. Nitrous oxide-induced slow and delta oscillations. Clin Neurophysiol. 2016;127:556–564.
Akeju O, Westover MB, Pavone KJ, et al. Effects of sevoflurane and propofol on frontal electroencephalogram power and coherence. Anesthesiology. 2014;121:990–998.
Foster BL, Liley DT. Nitrous oxide paradoxically modulates slow electroencephalogram oscillations: implications for anesthesia monitoring. Anesth Analg. 2011;113:758–765.
Purdon PL, Pierce ET, Mukamel EA, et al. Electroencephalogram signatures of loss and recovery of consciousness from propofol. Proc Natl Acad Sci U S A. 2013;110:E1142–E1151.
Barry RJ, Clarke AR, Johnstone SJ, Magee CA, Rushby JA. EEG differences between eyes-closed and eyes-open resting conditions. Clin Neurophysiol. 2007;118:2765–2773.
Kortelainen J, Koskinen M, Mustola S, Seppänen T. Effects of remifentanil on the spectrum and quantitative parameters of electroencephalogram in propofol anesthesia. Anesthesiology. 2009;111:574–583.
Austin PC. Balance diagnostics for comparing the distribution of baseline covariates between treatment groups in propensity-score matched samples. Stat Med. 2009;28:3083–3107.

Auteurs

Steven McGuigan (S)

From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.
the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia.

Lisbeth Evered (L)

From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.
the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia.

Brendan Silbert (B)

From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.
the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia.

David A Scott (DA)

From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.
the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia.

John R Cormack (JR)

From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.

Abarna Devapalasundaram (A)

From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.

David T J Liley (DTJ)

the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH