A Single-Center Experience with Forearm Arteriovenous Loop Grafts for Hemodialysis.
Humans
Female
Middle Aged
Male
Arteriovenous Shunt, Surgical
/ adverse effects
Forearm
/ blood supply
Vascular Patency
Graft Occlusion, Vascular
/ diagnostic imaging
Retrospective Studies
Blood Vessel Prosthesis Implantation
/ adverse effects
Risk Factors
Treatment Outcome
Time Factors
Renal Dialysis
/ adverse effects
Journal
Annals of vascular surgery
ISSN: 1615-5947
Titre abrégé: Ann Vasc Surg
Pays: Netherlands
ID NLM: 8703941
Informations de publication
Date de publication:
Nov 2022
Nov 2022
Historique:
received:
10
05
2022
revised:
15
06
2022
accepted:
23
06
2022
pubmed:
12
7
2022
medline:
25
2
2023
entrez:
11
7
2022
Statut:
ppublish
Résumé
Autogenous arteriovenous fistula (AVF) remains the standard of hemodialysis (HD) access; however, it cannot be reasonably obtained in all patients. For patients with contraindications to AVFs, prosthetic arteriovenous graft (AVG) remains an alternative. AVGs are plagued by high failure rates; however, there is a paucity of literature examining this. This study aims to examine a single-center review of outcomes of forearm loop AVGs in patients requiring HD access. A single institution, retrospective chart review was completed from 2012 to 2019, including demographics, end-stage renal disease etiology, brachial vessel diameters, and comorbidities. Logistic regression and Cox proportional hazard models were evaluated. Outcomes were defined as primary patency (time elapsed from graft creation until it was utilized as the patient's primary access), primary-assisted patency (time from primary access to intervention to maintain patency), and functional patency (time from graft placement until graft failure). Additionally, multinomial regression models were used to evaluate associations with categorical number of required interventions. Ninety-eight patients [mean age 61.8 (13.9) years, 42.9% female] were identified as having brachial artery to brachial vein AVG creation during the study period, of which 75% achieved primary patency. Primary-assisted patency was 0.36 [standard error (SE) 0.07] at 6 months and 0.12 (SE 0.05) at 1 year. Functional patency was 0.75 (SE 0.07) at 6 months and 0.43 (SE 0.09) at 1 year. No association between preoperative vessel diameters and primary-assisted or functional patency was observed. Interestingly, there was a significant negative association between previous ipsilateral access and achievement of primary patency with a 60% decrease in odds of achieving primary patency in patients with previous ipsilateral access [odds ratio 0.4, 95% confidence interval (CI) 0.1-0.9, P = 0.03]. There was also noted to be a significant association between the presence of an ipsilateral catheter and increased risk of subsequent abandonment of the AVG (hazard ratio 2.6, 95% CI 1.1-5.8, P = 0.02). Prosthetic forearm loop AVGs remain hindered in their utility as they show high rates of graft failure within a year of creation. A significant patient-specific factor leading to this was not clearly demonstrated. As guidelines change regarding the nature of dialysis access for patients on HD, these results draw into question the utility of prosthetic forearm loop grafts in patients requiring long-term HD access.
Sections du résumé
BACKGROUND
BACKGROUND
Autogenous arteriovenous fistula (AVF) remains the standard of hemodialysis (HD) access; however, it cannot be reasonably obtained in all patients. For patients with contraindications to AVFs, prosthetic arteriovenous graft (AVG) remains an alternative. AVGs are plagued by high failure rates; however, there is a paucity of literature examining this. This study aims to examine a single-center review of outcomes of forearm loop AVGs in patients requiring HD access.
METHODS
METHODS
A single institution, retrospective chart review was completed from 2012 to 2019, including demographics, end-stage renal disease etiology, brachial vessel diameters, and comorbidities. Logistic regression and Cox proportional hazard models were evaluated. Outcomes were defined as primary patency (time elapsed from graft creation until it was utilized as the patient's primary access), primary-assisted patency (time from primary access to intervention to maintain patency), and functional patency (time from graft placement until graft failure). Additionally, multinomial regression models were used to evaluate associations with categorical number of required interventions.
RESULTS
RESULTS
Ninety-eight patients [mean age 61.8 (13.9) years, 42.9% female] were identified as having brachial artery to brachial vein AVG creation during the study period, of which 75% achieved primary patency. Primary-assisted patency was 0.36 [standard error (SE) 0.07] at 6 months and 0.12 (SE 0.05) at 1 year. Functional patency was 0.75 (SE 0.07) at 6 months and 0.43 (SE 0.09) at 1 year. No association between preoperative vessel diameters and primary-assisted or functional patency was observed. Interestingly, there was a significant negative association between previous ipsilateral access and achievement of primary patency with a 60% decrease in odds of achieving primary patency in patients with previous ipsilateral access [odds ratio 0.4, 95% confidence interval (CI) 0.1-0.9, P = 0.03]. There was also noted to be a significant association between the presence of an ipsilateral catheter and increased risk of subsequent abandonment of the AVG (hazard ratio 2.6, 95% CI 1.1-5.8, P = 0.02).
CONCLUSIONS
CONCLUSIONS
Prosthetic forearm loop AVGs remain hindered in their utility as they show high rates of graft failure within a year of creation. A significant patient-specific factor leading to this was not clearly demonstrated. As guidelines change regarding the nature of dialysis access for patients on HD, these results draw into question the utility of prosthetic forearm loop grafts in patients requiring long-term HD access.
Identifiants
pubmed: 35817384
pii: S0890-5096(22)00322-3
doi: 10.1016/j.avsg.2022.06.003
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
286-294Subventions
Organisme : NIA NIH HHS
ID : R01 AG071803
Pays : United States
Informations de copyright
Copyright © 2022 Elsevier Inc. All rights reserved.