Non-covalent π-π functionalized Gii-sense
Chemisorption
Electrochemical impedance spectroscopy
Graphene foam
Inter-leukin 10
Label-free detection
Pyrenes
Journal
Biosensors & bioelectronics
ISSN: 1873-4235
Titre abrégé: Biosens Bioelectron
Pays: England
ID NLM: 9001289
Informations de publication
Date de publication:
15 Feb 2023
15 Feb 2023
Historique:
received:
08
09
2022
revised:
21
10
2022
accepted:
23
11
2022
pubmed:
13
12
2022
medline:
28
12
2022
entrez:
12
12
2022
Statut:
ppublish
Résumé
Monitoring Interleukin 10 (IL-10) is essential for understanding the vast responses of T-cells in cancer, autoimmunity, and internal homeostasis after physical stress. However, current diagnostic methods are complex and more focused on medical screening rather than point-of-care monitoring. Biosensors based on graphene's conductivity and flexibility are attractive to offer simple single-use and reduced handling. However, oxidation of its carbon lattice to develop functional moieties for biomolecule immobilization cuts down its electronic conductivity potential. In this work, the authors present a microfluidic lab-on-chip device for simple impedimetric monitoring of IL-10 based on graphene foam (GF) flexible electrodes. Graphene's structure was maintained by employing π-π non-covalent functionalization with pyrene carboxylic acid (PCA). Impedimetric measurements could be performed in low ionic strength phosphate-buffered saline (LI-PBS). The PCA-antibody modification showed to endure the incubation, measurement, and washing processes performed in the microfluidic device. Electrode modification and measurements were characterized by, electrochemical impedance spectroscopy (EIS), contact angle, and scanning electron microscopy. From the contact angle results, we found that the wettability of the graphene surface increased gradually after each modification step. Detection measurements performed in the 3D-printed microfluidic device showed a linear response between 10 fg/mL to 100 fg/mL with a limit of detection (LOD) of 7.89 fg/mL in artificial saliva. With these features, the device was used to quantify IL-10 samples by the standard addition method for 10 fg and 50 fg with recoveries between 82% and 99%. Specificity was evaluated towards interleukin 6, TNF-⍺ and bovine serum albumin.
Identifiants
pubmed: 36502717
pii: S0956-5663(22)00994-0
doi: 10.1016/j.bios.2022.114954
pii:
doi:
Substances chimiques
Graphite
7782-42-5
Interleukin-10
130068-27-8
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
114954Informations de copyright
Copyright © 2022 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.