A manikin-based assessment of loose-fitting powered air-purifying respirator performance at variable flow rates and work rates.


Journal

Journal of occupational and environmental hygiene
ISSN: 1545-9632
Titre abrégé: J Occup Environ Hyg
Pays: England
ID NLM: 101189458

Informations de publication

Date de publication:
07 2023
Historique:
pmc-release: 01 07 2024
medline: 8 8 2023
pubmed: 21 4 2023
entrez: 21 04 2023
Statut: ppublish

Résumé

Loose-fitting powered air-purifying respirators (PAPRs) are used in healthcare settings, although barriers to routine, everyday usage remain, including usability concerns and potential interference with work activities. Loose-fitting PAPRs are approved by the National Institute for Occupational Safety and Health (NIOSH) and must meet minimum performance requirements, including a minimum airflow requirement of 170 L/min. One course of action to address usability concerns is to allow for the use of PAPRs designed with reduced airflow rates. The primary objective of this study was to assess the effect of PAPR flow rate and user work rate on PAPR performance, using a manikin-based assessment method. PAPR performance was quantified using the "Manikin Fit Factor" (mFF), a ratio of the challenge aerosol concentration to the in-facepiece concentration. Flow rates from 50-215 L/min and low, moderate, and high work rates were tested. Two models of NIOSH Approved loose-fitting facepiece PAPRs were tested, both having an Occupational Safety and Health Administration Assigned Protection Factor (APF) or expected level of protection, of 25. A two-way analysis of variance with an effect size model was run for each PAPR model to analyze the effects of work rate and flow rate on PAPR performance. Flow rate and work rate were found to be significant variables impacting PAPR performance. At low and moderate work rates and flow rates below the NIOSH minimum of 170 L/min, mFF was greater than or equal to 250, which is 10 times the OSHA APF of 25 for loose-fitting facepiece PAPRs. At high work rates and flow rates below 170 L/min, mFF was not greater than or equal to 250. These results suggest that some loose-fitting facepiece PAPRs designed with a flow rate lower than the current NIOSH requirement of 170 L/min may provide respirator users with expected protection at low and moderate work rates. However, when used at high work rates, some loose-fitting facepiece PAPRs designed with lower flow rates may not provide the expected level of protection.

Identifiants

pubmed: 37084405
doi: 10.1080/15459624.2023.2205481
pmc: PMC10527853
mid: NIHMS1915957
doi:

Substances chimiques

Aerosols 0

Types de publication

Journal Article Research Support, U.S. Gov't, P.H.S.

Langues

eng

Sous-ensembles de citation

IM

Pagination

279-288

Subventions

Organisme : Intramural CDC HHS
ID : CC999999
Pays : United States

Références

Med Sci Sports Exerc. 2011 Aug;43(8):1575-81
pubmed: 21681120
J Occup Environ Hyg. 2019 Jul;16(7):440-445
pubmed: 31081727
J Occup Environ Hyg. 2006 Nov;3(11):631-41
pubmed: 17086668
Br J Anaesth. 2020 Jul;125(1):e171-e176
pubmed: 32340733
J Occup Environ Hyg. 2016;13(3):169-76
pubmed: 26554716
J Occup Environ Hyg. 2014;11(2):117-25
pubmed: 24369934
Respirology. 2005 Jan;10(1):107-10
pubmed: 15691247
J Int Soc Respir Prot. 2017;34(1):40-57
pubmed: 30498287
Am J Infect Control. 2021 Apr;49(4):492-499
pubmed: 33186678
Am J Infect Control. 2019 Jun;47(6):648-655
pubmed: 30638674
Workplace Health Saf. 2016 Aug;64(8):359-68
pubmed: 27462029
Am J Infect Control. 2016 Mar 1;44(3):340-2
pubmed: 26559735
Am J Infect Control. 2009 Dec;37(10):e5-e16
pubmed: 20004810

Auteurs

Kevin T Strickland (KT)

National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, Pennsylvania.

Michael S Bergman (MS)

National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, Pennsylvania.

Susan Xu (S)

National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, Pennsylvania.

Ziqing Zhuang (Z)

National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, Pennsylvania.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH