Micro-flow size-exclusion chromatography for enhanced native mass spectrometry of proteins and protein complexes.
Hyphenation
Low-flow chromatography
Native mass spectrometry
Protein characterization
Size-exclusion chromatography
Trap and elute
Journal
Analytica chimica acta
ISSN: 1873-4324
Titre abrégé: Anal Chim Acta
Pays: Netherlands
ID NLM: 0370534
Informations de publication
Date de publication:
25 Jul 2023
25 Jul 2023
Historique:
received:
15
11
2022
revised:
29
03
2023
accepted:
03
05
2023
medline:
29
5
2023
pubmed:
28
5
2023
entrez:
27
5
2023
Statut:
ppublish
Résumé
Size-exclusion chromatography (SEC) employing aqueous mobile phases with volatile salts at neutral pH combined with native mass spectrometry (nMS) is a valuable tool to characterize proteins and protein aggregates in their native state. However, the liquid-phase conditions (high salt concentrations) frequently used in SEC-nMS hinder the analysis of labile protein complexes in the gas phase, necessitating higher desolvation-gas flow and source temperature, leading to protein fragmentation/dissociation. To overcome this issue, we investigated narrow SEC columns (1.0 mm internal diameter, I.D.) operated at 15-μL/min flow rates and their coupling to nMS for the characterization of proteins, protein complexes and higher-order structures (HOS). The reduced flow rate resulted in a significant increase in the protein-ionization efficiency, facilitating the detection of low-abundant impurities and HOS up to 230 kDa (i.e., the upper limit of the Orbitrap-MS instrument used). More-efficient solvent evaporation and lower desolvation energies allowed for softer ionization conditions (e.g., lower gas temperatures), ensuring little or no structural alterations of proteins and their HOS during transfer into the gas phase. Furthermore, ionization suppression by eluent salts was decreased, permitting the use of volatile-salt concentrations up to 400 mM. Band broadening and loss of resolution resulting from the introduction of injection volumes exceeding 3% of the column volume could be circumvented by incorporating an online trap-column containing a mixed-bed ion-exchange (IEX) material. The online IEX-based solid-phase extraction (SPE) or "trap-and-elute" set-up provided on-column focusing (sample preconcentration). This allowed the injection of large sample volumes on the 1-mm I.D. SEC column without compromising the separation. The enhanced sensitivity attained by the micro-flow SEC-MS, along with the on-column focusing achieved by the IEX precolumn, provided picogram detection limits for proteins.
Identifiants
pubmed: 37244657
pii: S0003-2670(23)00545-7
doi: 10.1016/j.aca.2023.341324
pii:
doi:
Substances chimiques
Salts
0
Proteins
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
341324Commentaires et corrections
Type : ErratumIn
Informations de copyright
Copyright © 2023. Published by Elsevier B.V.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.