Fabrication trueness and internal fit of hybrid abutment crowns fabricated by using additively and subtractively manufactured resins.

Additive manufacturing Fabrication trueness Hybrid abutment crown Internal fit

Journal

Journal of dentistry
ISSN: 1879-176X
Titre abrégé: J Dent
Pays: England
ID NLM: 0354422

Informations de publication

Date de publication:
09 2023
Historique:
received: 08 04 2023
revised: 11 07 2023
accepted: 12 07 2023
medline: 22 8 2023
pubmed: 16 7 2023
entrez: 15 7 2023
Statut: ppublish

Résumé

To evaluate the fabrication trueness and internal fit of hybrid abutment crowns fabricated by using additively and subtractively manufactured restorative materials. A maxillary first premolar crown with a screw access channel was designed onto a digitized master titanium base abutment. This file was used to fabricate 40 crowns additively (Crowntec (CT) and VarseoSmile Crown Plus (VS)) or subtractively (Brilliant Crios (BC) and Vita Enamic (EN)) (n = 10). Crowns were digitized with an intraoral scanner and root mean square method was used to evaluate fabrication trueness. Master abutment and the crowns when seated on the abutment were also digitized with the same intraoral scanner and triple scan method was used to evaluate internal fit. Data were analyzed either with 1-way ANOVA (surface deviations) or Kruskal-Wallis (internal fit) tests (α= 0.05). CT had the highest overall, external, and marginal surface deviations (P≤.030), whereas BC had the lowest external (P≤.001) and VS and EN had the lowest marginal surface deviations (P≤.007). BC had the highest intaglio surface deviations (P<.001). BC and EN had higher average gap values CT and VS (P≤.006); however, the differences within additively and subtractively manufactured materials were nonsignificant (P≥.858). One of the tested additively manufactured resins (CT) resulted in mostly lower trueness than that of other materials. However, deviations at the intaglio and marginal surfaces were generally small and the maximum mean difference among test groups when average gap was considered was 17.4 µm. Therefore, clinical fit of hybrid abutment crowns fabricated with tested materials may be similar.

Identifiants

pubmed: 37453654
pii: S0300-5712(23)00207-5
doi: 10.1016/j.jdent.2023.104621
pii:
doi:

Substances chimiques

Titanium D1JT611TNE

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

104621

Informations de copyright

Copyright © 2023 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Münir Demirel (M)

Assistant Professor, Oral and Dental Health, Vocational School, Biruni University, Istanbul, Turkey.

Almira Ada Diken Türksayar (AA)

Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey; Guest Researcher, ADMiRE Research Center-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria.

Mustafa Borga Donmez (MB)

Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland. Electronic address: mustafa-borga.doenmez@unibe.ch.

Articles similaires

Humans Finite Element Analysis Orthodontic Anchorage Procedures Maxilla Tooth Movement Techniques
Phonons Titanium Oxides Zirconium Calcium Compounds

Effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques.

Eman Mostafa Awad, Mohamed Maamoun ElSheikh, Azza Abd El Moneim El-Segai
1.00
Dental Impression Technique Humans Dental Implants Computer-Aided Design Dental Impression Materials

Scalable ultrastrong MXene films with superior osteogenesis.

Sijie Wan, Ying Chen, Chaojie Huang et al.
1.00
Osteogenesis Animals Tensile Strength Titanium Mice

Classifications MeSH