Curcumin-Based Molecularly Imprinted Polymer Electropolymerized on Single-Use Graphite Electrode for Dipyridamole Analysis.


Journal

Molecules (Basel, Switzerland)
ISSN: 1420-3049
Titre abrégé: Molecules
Pays: Switzerland
ID NLM: 100964009

Informations de publication

Date de publication:
29 Sep 2024
Historique:
received: 16 08 2024
revised: 14 09 2024
accepted: 26 09 2024
medline: 16 10 2024
pubmed: 16 10 2024
entrez: 16 10 2024
Statut: epublish

Résumé

A new molecularly imprinted polymer (MIP)-based disposable electrochemical sensor for dipyridamole (DIP) determination was obtained. The sensor was rapidly prepared by potentiodynamic electrochemical polymerization on a pencil graphite electrode (PGE) using curcumin (CUR) as a functional monomer and DIP as a template molecule. After the optimization of the conditions (pH, monomer-template ratio, scan rate, number of cyclic voltammetric cycles applied in the electro-polymerization process and extraction time of the template molecule) for MIP formation, DIP voltammetric behavior at the modified electrode (MIP_PGE) was investigated. DIP oxidation took place in a pH-dependent, irreversible mixed diffusion-adsorption controlled process. Differential pulse voltammetry (DPV) and adsorptive stripping differential pulse voltammetry (AdSDPV) were used to quantify DIP from pharmaceutical and tap water samples. Under optimized conditions (Britton-Robinson buffer at pH = 3.29), the obtained linear ranges were 5.00 × 10

Identifiants

pubmed: 39407560
pii: molecules29194630
doi: 10.3390/molecules29194630
pii:
doi:

Substances chimiques

Graphite 7782-42-5
Curcumin IT942ZTH98
Molecularly Imprinted Polymers 0
Dipyridamole 64ALC7F90C
Polymers 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Subventions

Organisme : Ministerul Cercetării și Inovării
ID : PN 23-02-0101/2024-Contract No. 7N/2023

Déclaration de conflit d'intérêts

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Auteurs

Daniel Preda (D)

Doctoral School of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica Bucharest, Gheorghe Polizu Street 1-7, District 1, 011061 Bucharest, Romania.

Gabriel Lucian Radu (GL)

National Institute of Biological Sciences, Centre of Bioanalysis, Splaiul Independentei 296, District 6, 060031 Bucharest, Romania.

Emilia-Elena Iorgulescu (EE)

Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Avenue 90-92, District 5, 050663 Bucharest, Romania.

Mihaela-Carmen Cheregi (MC)

Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Avenue 90-92, District 5, 050663 Bucharest, Romania.

Iulia Gabriela David (IG)

Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Avenue 90-92, District 5, 050663 Bucharest, Romania.

Articles similaires

Aspergillus Hydrogen-Ion Concentration Coculture Techniques Secondary Metabolism Streptomyces rimosus
Semiconductors Photosynthesis Polymers Carbon Dioxide Bacteria
Curcumin Spinal Cord Injuries Humans Animals Neural Stem Cells
Animals Huntington Disease Mitochondria Neurons Mice

Classifications MeSH