Outbreaks of infection related to flexible endoscopes are well described. However, flexible endoscopy also requires the use of ancillary equipment such as irrigation plugs. These are potential vectors...
Laboratory, clinical and decontamination unit records were reviewed, and audits of the decontamination unit were performed. Flexible cystoscopes and irrigation plugs were assessed for contamination. R...
Three strains of P. aeruginosa were isolated from five irrigation plugs but none of the flexible cystoscopes. No acquired resistance mechanisms were detected. Fifteen confirmed infections occurred, in...
Ancillary equipment can represent an important vector for infection, and should be considered during outbreak investigations. Users should review the manufacturer's instructions for reprocessing ancil...
(1) Background: Bacterial contamination has been shown to occur during angiographies, although data on its frequency and relevance are sparse. Our aim was to evaluate the incidence of bacterial contam...
To compare the effectiveness of disinfection protocols utilizing a ultraviolet (UV) Smart D60 light system with Impelux™ technology with a standard Cidex ortho-phthalaldehyde (OPA) disinfection protoc...
Two hundred FFLs were tested for bacterial contamination after routine use, and another 200 FFLs were tested after disinfection with one of four methods: enzymatic detergent plus Cidex OPA (standard),...
After routine use, approximately 56% (112/200) of FFLs were contaminated, with an average contamination level of 9,973.7 ± 70,136.3 CFU/mL. The standard reprocessing method showed no positive cultures...
Disinfection protocols utilizing UV Smart D60 were as effective as the standard chemical disinfection protocol using Cidex OPA....
NA Laryngoscope, 133:3512-3519, 2023....
Forced-air drying (FAD) cabinets are recommended for storage of reprocessed endoscopes, but financial constraints prevent their universal application. The study aimed to determine bacterial contaminat...
Eight FG in clinical use in an endoscopy service of a large Brazilian hospital were sampled: immediately "Time zero" (N = 50), 12 h "Time 1" (N = 25), and 60 h "Time 2" (N = 25) after reprocessing. Fo...
Bacterial contamination in times "1" and "2" was 5.9 and 16.1 times greater than that of "Time zero," respectively. Number of positive cultures in media with and without neutralizer was similar at tim...
Bacterial contamination was detected on reprocessed FG stored in non-FAD cabinets overnight (12 h) and increased with longer storage time (60 h). The contamination source is likely to be bacteria in b...
Recent reports implicated heater-cooler units (HCUs), which are used for warming infusions, blood or in extracorporeal membrane oxygenation devices, as a possible origin of healthcare-associated infec...
To analyse water from infusion heating devices (IHDs) for bacterial contamination, and to determine if IHDs are a potential source in the transmission of HAIs....
Thermal transfer fluid (TTF; 300-500 mL) was collected from the reservoirs of 22 independent IHDs and processed on different selective and non-selective media for colony count and identification of ba...
Bacterial growth was observed in all 22 TTF samples after cultivation at 22 °C and 36 °C. Pseudomonas aeruginosa was the most frequent pathogen identified, present in 13.64% (3/22) of samples at >100 ...
Contamination of TTF represents a germ reservoir in a sensitive setting. Handling errors of IHDs may lead to the distribution of opportunistic or facultative bacterial pathogens, increasing the risk o...
Studies have shown that contamination of surfaces by illicit drugs frequently occurs in forensic laboratories when manipulating seized samples as well as in pharmacies and hospitals when preparing med...
We investigated pre and post cleaning contamination by heroin and cocaine and their degradation products 6-monoacetylmorphine and benzoylecgonine on different surfaces (tables, counters, computers and...
Medium to heavy contamination has been detected on most surfaces and door handles; as expected, air contamination was particularly high in the smoking room. Drug levels were < LOD to very low in the u...
The cleaning efficiency of the surfaces, carried out by staff and drug users after drug consumption, was often not satisfactory. The very low drug levels in hair indicate that acute health risks for s...
The risk of virus transmission via the touching of contaminated masks has long been assumed by infection control teams. Yet, robust evidence to support this belief has been lacking. This risk was inve...
Dental Unit Water Line (DUWL) deliver water to different handpieces in a dental unit. The water in DUWL circulates in a closed system, where it is taken from a container. The quality of dental water i...
To assess the microbial contamination in the DUWL among dental clinics in Chennai....
An in vitro study was conducted on 60 water samples from 20 dental clinics in Chennai in December 2019. Water samples were collected from three different sources of the Dental unit according to ADA gu...
Legionella was the most prevalent microorganism with 70% prevalence in a three-way syringe and 50% in scaler and airotor, followed by Pseudomonas aeruginosa and Acinetobacter with 10% prevalence in sc...
Most of the dental units were contaminated with Aspergillus, Legionella, Pseudomonas aeruginosa and Acinetobacter which pose a serious threat to the patients as well as the dentists....
Earlier studies showed net cost saving from anesthesia practitioners' use of a bundle of infection prevention products, with feedback on monitored Staphylococcus aureus intraoperative transmission. ES...
The retrospective cohort study used bacterial count data from nine hospitals, 43 months, and 448 ESKAPE pathogen transmission events within anesthesia areas of 86 operating rooms. Transmission was mea...
There were 203 transmission events with S. aureus, 72 with Enterococcus, and 173 with gram negatives. ESKAPE pathogens in the nose contributed to transmission for 50% (99% confidence limit ≥45%) of ca...
To prevent intraoperative ESKAPE pathogen transmission, anesthesia practitioners would need to address all five categories of infection control approaches: nasal antisepsis (e.g., povidone-iodine appl...
Contamination of the breathing circuit and medication preparation surface of an anesthesia machine can increase the risk of cross-infection....
To evaluate the contamination of the anesthetic medication preparation surface, respiratory circuits, and devices used in general anesthesia with assisted mechanical ventilation....
Cross-sectional, quantitative study conducted at the surgical center of a philanthropic hospital, of medium complexity located in the municipality of Três Lagoas, in the eastern region of the State of...
Eighty-two microbiological samples were collected from the breathing circuits. After repeating the samples in different culture media, 328 analyses were performed....
A higher occurrence of E. coli, Enterobacter spp., Pseudomonas spp., Staphylococcus aureus, and Streptococcus pneumoniae (P < 0.001) were observed. Variations were observed depending on the culture me...
The study findings underscore the inadequate disinfection of the inspiratory and expiratory branches, highlighting the importance of stringent cleaning and disinfection of high-touch surfaces....