Department of Functional Sciences, "Victor Babeș" University of Medicine and Pharmacy of Timișoara, 300041 Timisoara, Romania.
Center for Modeling Biological Systems and Data Analysis, "Victor Babeș" University of Medicine and Pharmacy of Timisoara, 300041 Timisoara, Romania.
Department of Rehabilitation, Physical Medicine and Rheumatology, Research Center for Assessment of Human Motion, Functionality and Disability, "Victor Babeș" University of Medicine and Pharmacy of Timișoara, 300041 Timisoara, Romania.
Publications dans "Pléthysmographie d'impédance" :
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
To determine the validity of bioelectrical impedance analysis (BIA) in quantifying fat-free mass (FFM) compared to air-displacement plethysmography (ADP) in patients with a motor neurone disease (MND)...
FFM of 140 patients diagnosed with MND was determined by ADP using the BodPod (i.e. the gold standard), and by BIA using the whole-body Bodystat. FFM values were translated to predicted resting energy...
Despite the high correlation between ADP and BIA (...
BIA systematically overestimates FFM in patients with MND. Although the differences are limited with ADP, underscoring the utility of BIA for research, overestimation of fat-free mass may have consequ...
The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device...
Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analyzed. Slope parameters and the areas under the curve of characteristic sections of pulse waves ...
In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-...
Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and th...
We propose a new speckle-based plethysmography technique, termed rolling shutter speckle plethysmography (RSSPG), which can quantitatively measure the velocity and volume fluctuations of blood flow du...
The accurate recording of respiratory rate (RR) without contact is important for patient care. The current methods for RR measurement such as capnography, pneumography, and plethysmography require pat...
To develop a cuffless method for estimating blood pressure (BP) from fingertip strain plethysmography (SPG) recordings....
A custom-built micro-electromechanical systems (MEMS) strain sensor is employed to record heartbeat-induced vibrations at the fingertip. An XGboost regressor is then trained to relate SPG recordings t...
Mean absolute errors (MAEs) of 3.88 mmHg and 5.45 mmHg were achieved for DBP and SBP estimations, respectively, in the 5-CV setting. LSOCV yielded MAEs of 8.16 mmHg for DBP and 16.81 mmHg for SBP. Thr...
The findings suggest high potential for SPG-based BP estimation at the fingertip....
This study presents a fundamental step towards the augmentation of optical sensors that are susceptible to dark skin tones....
Pregnancy complications related to hypertension can affect both mother and newborn. Pulse wave attenuation (PWA) captured through fingertip photoplethysmography (PPG) provide valuable insights into ma...
PWA dynamics were assessed on overnight polysomnography-derived PPG signals from a cohort of 2714 pregnant women (mean age: 26.8 ± 5.5 years) enrolled in the Nulliparous Pregnancy Outcomes Study: Moni...
Odds ratio (OR) analysis-adjusted common confounders indicates that an average PWAduration greater than 8.74 s was associated with the increased risk of gestational hypertension [OR = 1.75 (1.27-2.39)...
PWA attenuation dynamics during early pregnancy predict the risk of developing gestational hypertension and diabetes condition for women in their later trimesters. Potentially obtainable from smart we...
In each cardiopulmonary exercise test (CPET), resting spirometry is performed in advance. In patients with a congenital heart defect (CHD), lung volumes are often impaired. This study investigates cor...
Data from 102 patients (23.8 ± 10.4 years of age, 39 female) with various forms of CHD were examined from April 2018 to October 2022. All patients underwent spirometry (measuring forced vital capacity...
Fifty-five% of all patients had normal results in lung function and 45% had normal peak oxygen uptake (≥ 80% predicted in peak VO...
Spirometry and exercise capacity positively correlate, also in CHD patients. However, body plethysmography does not provide additional or improved prediction and is therefore only recommended in notew...
Chronic Venous Insufficiency (CVI) presents a various clinical symptoms and treatment options. Although it is generally known which treatment option is more appropriate in which situations in CVI, it ...
This retrospective study was conducted at Bursa Heart and Arrhythmia Hospital, involving 721 consecutive patients diagnosed with CVI and with Endovenous Laser Ablation (EVLA) indication. The patients ...
The study included 263 male and 458 female patients with a mean age of 52.37 ± 12.26 years. Significant differences were observed between Group 1 (above knee reflux) and Group 2 (below knee reflux) pa...
D-PPG shows potential as a valuable tool in the diagnosis and treatment of CVI. By providing information about venous hemodynamics and volume changes, it can assist in optimizing treatment decisions, ...
The purpose of this study was to evaluate the feasibility and accuracy of remote Video Plethysmography (VPPG) for contactless measurements of blood pressure (BP) and heart rate (HR) in adult surgical ...
Elevated nocturnal blood pressure (BP) is a risk factor for cardiovascular disease (CVD) and mortality. Cuffless BP assessment aided by machine learning could be a desirable alternative to traditional...
Sixty-eight healthy adults with no apparent sleep or CVD (53% male), with a median (IQR) age of 29 (23-46 years), underwent overnight polysomnography (PSG) with fingertip PPG and ambulatory blood pres...
Our model achieved the highest out-of-sample performance with a window length of 7 s across window lengths explored (60 s, 30 s, 15 s, 7 s, and 3 s). The mean absolute error (MAE ± STD) was 5.72 ± 4.5...
Our results highlight the potential of machine learning-based nocturnal BP prediction using single-channel fingertip PPG in healthy adults. The accuracy of the predictions demonstrated that our cuffle...