Division of Urogynecology and Pelvic Floor Disorders, Department of Subspecialty Care for Women's Health, Women's Health Institute, Cleveland Clinic Foundation, Cleveland, OH. Electronic address: wallacs8@ccf.org.
Division of Urogynecology and Pelvic Reconstructive Surgery, Department of Obstetrics and Gynecology, Stanford University School of Medicine, Stanford, CA.
Department of Obstetrics and Gynecology, Division of Female Pelvic Medicine and reconstructive Surgery Northwestern University, Feinberg School of Medicine Chicago, 250 E. Superior, Chicago, IL 60611, USA. Electronic address: Christina.LewickyGaupp@nm.org.
Department of Gynecology and Obstetrics, Emory University School of Medicine, Emory Gyn/Ob Clinic, 1365 Clifton Road, Bldg A, 4th Floor, Attention Daphne Blow, Atlanta, GA, 30322, USA.
Department of Obstetrics and Gynecology, Tampere University Hospital, Tampere, Finland; Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Department of Obstetrics and Gynecology, Mayo Clinic, Rochester, MN; Department of Urology, Mayo Clinic, Rochester, MN. Electronic address: Linder.Brian@mayo.edu.
Urogynecology/Department of Obstetrics and Gynecology, Female Pelvic Medicine and Reconstructive Surgery (Urogynecology), Women's Health Institute, Cleveland, Ohio.
Department of Surgery, Stanford Pelvic Health Center, Stanford University, Stanford, California.
Despite the rapid adoption of transcatheter aortic valve replacement (TAVR), the frequency and clinical outcomes of reoperation after TAVR are not well-described....
Between 2011 and 2020, 1719 patients underwent a TAVR at our institution. Among these, 32 patients (2%) required a reoperation. Additionally, 16 patients who received a TAVR at another institution rec...
Primary reoperations included 37 TAVR valve explants (TAVR-explant; 77%) with surgical aortic valve replacement (SAVR), 8 mitral repairs/replacements (17%), 2 coronary artery bypass grafting procedure...
The clinical impact of post-TAVR reoperation remains substantial despite the lower frequency of unplanned aortic repair over time. The necessity of reoperations or unfavorable repeat TAVR anatomy appe...
In this video tutorial, the technical details for the implantation of the Freestyle stentless bioprosthesis are outlined based on the case of a 76-year-old male patient with symptomatic stenosis of a ...
Transcatheter aortic valve implant (TAVI) is gaining momentum in the treatment of severe, symptomatic aortic valve stenosis, and its indication is expanding to lower surgical risk individuals, who are...
We analyzed all consecutive patients (n = 408) who underwent transfemoral TAVI at a single, high-volume center, between 2007 and 2014. Study objectives were all-cause death and bioprosthetic valve fai...
At a median follow-up of 1821 days, overall mortality was 64.5%, with cardiovascular disease accounting for roughly half of total deaths. Valve-related deaths occurred in 10 patients. Seventeen patien...
In the present unselected, all-comers cohort, TAVI bioprostheses appeared to have excellent durability at long-term follow-up....
Aortic valve stenosis is the most common adult valve disease in industrialized countries. The aging population and the increase in comorbidities urge the development of safer alternatives to the curre...
Assess the clinical and hemodynamic performance, safety, and durability of the Perceval® prosthetic valve....
This single-center retrospective longitudinal cohort study collected data from all adult patients with aortic valve disease who underwent aortic valve replacement with a Perceval® prosthetic valve bet...
Overall mean cross-clamp and cardiopulmonary bypass times were 33.31 ± 14.09 min and 45.55 ± 19.04 min, respectively. Mean intensive care unit and hospital stay were 3.32 ± 3.24 days and 7.70 ± 5.82 d...
Our study confirms the excellent clinical and hemodynamic performance and safety of a truly sutureless aortic valve, up to a 5-year follow-up. These results were consistent in isolated and concomitant...
Surgical robots have been utilized to facilitate a truly minimally invasive approach in cardiac surgery. Robotic aortic valve replacement allows for a totally endoscopic approach with better visualiza...
Isolated redo surgery for degenerated tricuspid bioprosthesis is of very high risk. We aimed to evaluate the safety and efficacy of transcatheter valve-in-valve (TVIV) implantation using a novel ballo...
A prospective multicenter study was conducted to enroll patients with degenerated tricuspid bioprostheses. A total of 12 patients underwent TVIV implantation using the Renato valve system via transfem...
The median age was 68.2 years, and 75.0% were female. Six patients had a history of rheumatic left-sided valve surgery and late tricuspid valve replacement. The median preoperative Society of Thoracic...
TVIV implantation with the Renato valve was a safe and effective treatment for degenerated bioprostheses in high-risk patients....
Aortic valve replacement (AVR) is one of the most common open-heart surgical procedures. The durability of the tissue valve in the aortic position is crucial in AVR and transcatheter AVR. We reviewed ...
A retrospective analysis was conducted where hemodynamic deterioration was evaluated and compared using transthoracic echocardiography, including pressure gradients and effective orifice area. Kaplan-...
The study included 133 Trifecta, 156 Epic, and 321 Magna Ease valves. Seventy-six percent (1941/2551) of patients had to be excluded due to insufficient echo data. Through univariate analysis, 34% (21...
All three valve types demonstrated structural valve deterioration on echocardiographic follow-up with significant differences in rate. The Magna Ease appeared to have the highest durability, and the E...
Modern multi-slice computed tomography (CT) has increased the detection of hypo-attenuated leaflet thickening (HALT). Furthermore, HALT's impact on transcatheter or surgical biological aortic valve (A...
The Inspiris Resilia (Edwards Lifesciences LLC) bioprosthesis has gained widespread use in the aortic position; however no robust data are available about its use in the pulmonary position....
We reviewed our outcomes for the Inspiris Resilia in the pulmonary position between August 2019 and October 2021....
Twenty-seven patients (15 female patients [56%]; mean age, 22.26 ± 14.99 years) were included. The most common original pathology was tetralogy of Fallot (13 patients, 48%). Five patients (18.5%) had ...
The early data regarding the Inspiris Resilia bioprosthesis use in the pulmonary position is concerning. The prosthesis design may not be suitable for low-pressure circulation, or modification of its ...
Aortic stenosis remains the number one heart valve pathology. The drive to improve the surgical outcomes brought to focus rapid deployment valves (RDV), which reduce aortic cross-clamping and cardio-p...
Retrospective analysis of associated conductions disorders and PPM implantation rates, as well as post-operative outcomes of all patients undergoing isolated aortic valve replacement between April 201...
We studied 201 patients. The majority of conduction abnormalities were left bundle branch block (54,0%). Twenty-six PPM were implanted (12,6%). Pre-operative characteristic between the groups were sim...
PPM implantation rates with RDV are relatively high and are associated with prolonged hospital and ICU stays, postoperative stroke rates and requirement of aminergic support. Their use should be made ...