NCI RAS Initiative, Cancer Research Technology Program, Frederick National Laboratory for Cancer Research, Leidos Biomedical Research, Inc., Frederick, MD 21701, USA.
NCI RAS Initiative, Cancer Research Technology Program, Frederick National Laboratory for Cancer Research, Leidos Biomedical Research, Inc., Frederick, MD 21701, USA.
NCI RAS Initiative, Cancer Research Technology Program, Frederick National Laboratory for Cancer Research, Leidos Biomedical Research, Inc., Frederick, MD 21701, USA.
NCI RAS Initiative, Cancer Research Technology Program, Frederick National Laboratory for Cancer Research, Leidos Biomedical Research, Inc., Frederick, MD 21701, USA; Helen Diller Family Comprehensive Cancer Center, University of California, San Francisco, San Francisco, CA 94158, USA. Electronic address: frank.mccormick@ucsf.edu.
To evaluate the effect of treatment on forearm rotation, torque muscle strength can be assessed using an isokinetic device (IKD) or a wrist dynamometer (WD). The aims of this study were 1) to determin...
The Constant score (CS) is often used clinically to assess shoulder function and includes a muscle strength assessment only for abduction. The aim of this study was to evaluate the test-retest reliabi...
Ten young healthy subjects participated in this study. Isometric shoulder muscle strength was measured during 3 repetitions for abduction at 10° and 30° abduction in the scapular plane (with extended ...
Muscle strength did not differ between tests (P > .05) with good to very good reliabilities for abduction at 10° and 30°, external rotation and internal rotation (ICC >0.7 for all). A moderate correla...
Shoulder muscle strength for abduction and rotation measured with the Biodex dynamometer are reproducible and correlate with the strength assessment of the CS. Therefore, these isometric muscle streng...
In attempts to improve the quality of life of women, continuous projects are sought between rehabilitation intervention and engineering. Using the knowledge of the pelvic floor muscle (PFM) physiology...
A PFM probe is designed, 3D printed, assembled, and tested in ten women to assess its acceptability and usability. The feedback from the usability study is used to optimize the PFM probe design. A vag...
Force measurements are made using a load cell. Wireless communication is performed through a Bluetooth low energy transceiver v5.0, with a corresponding interface on both computer and smartphone. The ...
The testing results showed that the newly designed system has the potential to measure the PFM function in functional conditions such as the standing position....
The purpose of this study was to assess the correlation, concurrent validity, and agreement between the isometric cervical force measurements obtained with fixed and portable dynamometers in asymptoma...
Fifty asymptomatic individuals performed 3 maximal isometric contractions for flexion, extension, and lateral flexion of the cervical spine using fixed and portable dynamometers. The correlation and c...
Isometric cervical force measurements obtained with the fixed dynamometer and portable dynamometer showed a moderately to highly significant correlation for flexion (r...
The neck strength measurements obtained with the fixed and portable dynamometers demonstrated high to moderate correlation and had moderate to good comparability for asymptomatic participants. However...
The Handheld Dynamometer (HHD) has the potential to overcome some of the logistic and economic limitations of isokinetic dynamometers for measuring knee extension muscle strength. However, its reliabi...
Twenty-nine patients admitted in an inpatient Physical Medicine and Rehabilitation unit were consecutively included in this cross-sectional study. Two experienced and two inexperienced physicians made...
Intra and inter-rater ICC were overall high (≥ 0.950 and 0.927, respectively). Higher values were found when average of two measurements were made for estimating intra-rater ICC (ICC = 0.978; 95%CI = ...
Handheld Dynamometer seems to be a reliable option to measure knee extension muscle strength, particularly when two measurements are performed and their average is reported....
Scapular protraction strength can be evaluated using a hand-held dynamometer (HHD). However, it is necessary to measure the reliability of HHD in individuals with shoulder pain and to minimize the lim...
Fifty individuals with unilateral symptoms of subacromial pain syndrome (20 men, aged 40.5 ± 15.3 years) were evaluated in two sessions using the belt-stabilized HHD for maximum isometric strength of ...
The intra- and interrater HHD reliability were excellent for all measurements ranging from 0.88 to 0.96 (SEM = 2.0-4.0 kg; %SEM 12 to 17; MDC = 6-11 kg)....
Belt-stabilized HHD is reliable for the assessment of scapular protraction strength in individuals with subacromial pain syndrome in both the sitting and supine positions....
Long-lever shoulder strength tests may aid clinical decision-making regarding return to sport after a shoulder injury. The Athletic Shoulder Test (AST) was developed to measure force production in 3 p...
Validity and reliability study....
Twenty-seven participants with no history of upper limb injury performed the test in a randomized order using the Kinvent HHD and force plates. Each condition was assessed 3 times, and peak force was ...
The Kinvent HHD is reliable when measuring force (intraclass correlation coefficient [ICC] ≥ .80), torque (ICC ≥ .84), and normalized torque (ICC ≥ .64) during the AST. The Kinvent HHD is also valid w...
The Kinvent HHD is a reliable tool when used to measure force, torque, and normalized torque in the AST. Furthermore, given the lack of significant difference between trials, clinicians can use one te...
Isokinetic strength assessment of the rotator cuff muscle is frequently applied in a variety of shoulder postures, but none of these consider muscular architecture, which is one of the most important ...
A total of 54 healthy males with a mean age of 21.0 ± 1.2 years and mean body mass index of 22.8 ± 1.7 kg/m...
The correlations between the 2 techniques for assessing concurrent validity ranged from 0.908 to 0.994. The values obtained from the MABP were higher than those obtained in the SNP. There was no syste...
In conclusion, the MABP can be used to assess the isokinetic strength of the rotator cuff muscles safely and confidently, with increased quantities of force being released and measurement at optimal m...
Muscle strength is routinely measured in patients with neuromuscular disorders by hand-held dynamometry incorporating a wireless load cell to evaluate disease severity and therapeutic efficacy, with m...
Handgrip strength (HGS) is an indicator of muscular strength, used in the diagnosis of sarcopenia, undernutrition, and physical frailty as well as recovery. Typically, the maximum HGS value is used; h...
A systematic review was performed including studies whose participants' HGS was assessed with a digital or adapted dynamometer. The outcome measures were HGS profile indicators calculated from the for...
a total of 15 studies were included, and the following indicators were identified: grip fatigue, fatigability index, fatigue rate, fatigue resistance, time to 80% maximal voluntary contraction, platea...
Various indicators based on the force-time curve can be assessed through digital or adapted dynamometers. Future research should analyze these indicators to understand their implications for muscle fu...