A mobile health monitoring-and-treatment system based on integration of the SSN sensor ontology and the HL7 FHIR standard.
Clinical decision support system
Diabetes treatment
Mobile health
Ontology
Semantic interoperability
Journal
BMC medical informatics and decision making
ISSN: 1472-6947
Titre abrégé: BMC Med Inform Decis Mak
Pays: England
ID NLM: 101088682
Informations de publication
Date de publication:
10 05 2019
10 05 2019
Historique:
received:
17
01
2019
accepted:
31
03
2019
entrez:
12
5
2019
pubmed:
12
5
2019
medline:
18
12
2019
Statut:
epublish
Résumé
Mobile health (MH) technologies including clinical decision support systems (CDSS) provide an efficient method for patient monitoring and treatment. A mobile CDSS is based on real-time sensor data and historical electronic health record (EHR) data. Raw sensor data have no semantics of their own; therefore, a computer system cannot interpret these data automatically. In addition, the interoperability of sensor data and EHR medical data is a challenge. EHR data collected from distributed systems have different structures, semantics, and coding mechanisms. As a result, building a transparent CDSS that can work as a portable plug-and-play component in any existing EHR ecosystem requires a careful design process. Ontology and medical standards support the construction of semantically intelligent CDSSs. This paper proposes a comprehensive MH framework with an integrated CDSS capability. This cloud-based system monitors and manages type 1 diabetes mellitus. The efficiency of any CDSS depends mainly on the quality of its knowledge and its semantic interoperability with different data sources. To this end, this paper concentrates on constructing a semantic CDSS based on proposed FASTO ontology. This realistic ontology is able to collect, formalize, integrate, analyze, and manipulate all types of patient data. It provides patients with complete, personalized, and medically intuitive care plans, including insulin regimens, diets, exercises, and education sub-plans. These plans are based on the complete patient profile. In addition, the proposed CDSS provides real-time patient monitoring based on vital signs collected from patients' wireless body area networks. These monitoring include real-time insulin adjustments, mealtime carbohydrate calculations, and exercise recommendations. FASTO integrates the well-known standards of HL7 fast healthcare interoperability resources (FHIR), semantic sensor network (SSN) ontology, basic formal ontology (BFO) 2.0, and clinical practice guidelines. The current version of FASTO includes 9577 classes, 658 object properties, 164 data properties, 460 individuals, and 140 SWRL rules. FASTO is publicly available through the National Center for Biomedical Ontology BioPortal at https://bioportal.bioontology.org/ontologies/FASTO . The resulting CDSS system can help physicians to monitor more patients efficiently and accurately. In addition, patients in rural areas can depend on the system to manage their diabetes and emergencies.
Sections du résumé
BACKGROUND
Mobile health (MH) technologies including clinical decision support systems (CDSS) provide an efficient method for patient monitoring and treatment. A mobile CDSS is based on real-time sensor data and historical electronic health record (EHR) data. Raw sensor data have no semantics of their own; therefore, a computer system cannot interpret these data automatically. In addition, the interoperability of sensor data and EHR medical data is a challenge. EHR data collected from distributed systems have different structures, semantics, and coding mechanisms. As a result, building a transparent CDSS that can work as a portable plug-and-play component in any existing EHR ecosystem requires a careful design process. Ontology and medical standards support the construction of semantically intelligent CDSSs.
METHODS
This paper proposes a comprehensive MH framework with an integrated CDSS capability. This cloud-based system monitors and manages type 1 diabetes mellitus. The efficiency of any CDSS depends mainly on the quality of its knowledge and its semantic interoperability with different data sources. To this end, this paper concentrates on constructing a semantic CDSS based on proposed FASTO ontology.
RESULTS
This realistic ontology is able to collect, formalize, integrate, analyze, and manipulate all types of patient data. It provides patients with complete, personalized, and medically intuitive care plans, including insulin regimens, diets, exercises, and education sub-plans. These plans are based on the complete patient profile. In addition, the proposed CDSS provides real-time patient monitoring based on vital signs collected from patients' wireless body area networks. These monitoring include real-time insulin adjustments, mealtime carbohydrate calculations, and exercise recommendations. FASTO integrates the well-known standards of HL7 fast healthcare interoperability resources (FHIR), semantic sensor network (SSN) ontology, basic formal ontology (BFO) 2.0, and clinical practice guidelines. The current version of FASTO includes 9577 classes, 658 object properties, 164 data properties, 460 individuals, and 140 SWRL rules. FASTO is publicly available through the National Center for Biomedical Ontology BioPortal at https://bioportal.bioontology.org/ontologies/FASTO .
CONCLUSIONS
The resulting CDSS system can help physicians to monitor more patients efficiently and accurately. In addition, patients in rural areas can depend on the system to manage their diabetes and emergencies.
Identifiants
pubmed: 31077222
doi: 10.1186/s12911-019-0806-z
pii: 10.1186/s12911-019-0806-z
pmc: PMC6511155
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
97Références
Stud Health Technol Inform. 2017;235:451-455
pubmed: 28423833
Sensors (Basel). 2014 Mar 07;14(3):4560-84
pubmed: 24608002
J Biomed Inform. 2012 Feb;45(1):184-98
pubmed: 21925288
Int J Med Inform. 2017 Jun;102:35-49
pubmed: 28495347
IEEE Trans Inf Technol Biomed. 2010 Sep;14(5):1216-26
pubmed: 20615815
Curr Diab Rep. 2016 Sep;16(9):83
pubmed: 27457238
J Biomed Semantics. 2017 Sep 19;8(1):41
pubmed: 28927443
J Med Syst. 2016 Dec;40(12):259
pubmed: 27722974
Diabetes Technol Ther. 2016 Feb;18(2):59-67
pubmed: 26645932
IEEE J Biomed Health Inform. 2019 Mar;23(2):867-873
pubmed: 29993759
Diabetes Res Clin Pract. 2019 Mar;149:39-46
pubmed: 28951337
Nutrients. 2018 Jan 22;10(1):
pubmed: 29361766
Can J Diabetes. 2018 Apr;42 Suppl 1:S234-S246
pubmed: 29650103
Med Sci Sports Exerc. 2011 Aug;43(8):1575-81
pubmed: 21681120
J Biomed Inform. 2018 Jan;77:133-144
pubmed: 29269275
BMC Med. 2015 May 06;13:106
pubmed: 25943590
J Biomed Inform. 2017 Aug;72:45-59
pubmed: 28676255
J Biomed Inform. 2018 Feb;78:134-143
pubmed: 29246790
Curr Diab Rep. 2018 May 10;18(7):38
pubmed: 29748905
J Med Syst. 2016 Sep;40(9):210
pubmed: 27520615
IEEE Trans Inf Technol Biomed. 2009 Nov;13(6):990-6
pubmed: 19643715
Comput Biol Med. 2016 Apr 1;71:86-96
pubmed: 26897071
Diabetes Care. 2013 Jul;36(7):1851-8
pubmed: 23801798
BMC Med Inform Decis Mak. 2018 Aug 31;18(1):76
pubmed: 30170591
J Med Syst. 2016 May;40(5):118
pubmed: 27002818
Can J Diabetes. 2016 Feb;40(1):95-104
pubmed: 26455762
Diabetes Spectr. 2014 Feb;27(1):9-20
pubmed: 26246751
Curr Diab Rep. 2017 Aug 23;17(10):92
pubmed: 28836234
Comput Methods Programs Biomed. 2017 Jun;144:37-48
pubmed: 28495005
Comput Methods Programs Biomed. 2018 Jul;160:95-101
pubmed: 29728251
Diabetes Technol Ther. 2008 Jun;10(3):160-8
pubmed: 18473689
J Biomed Inform. 2012 Jun;45(3):544-56
pubmed: 22406009
Proc Natl Acad Sci U S A. 1918 Dec;4(12):370-3
pubmed: 16576330
Sensors (Basel). 2017 Jul 06;17(7):
pubmed: 28684686
J Diabetes Sci Technol. 2014 Sep;8(5):1035-41
pubmed: 24876436
Sensors (Basel). 2016 Nov 24;16(12):
pubmed: 27886122
Stud Health Technol Inform. 2010;160(Pt 2):1065-9
pubmed: 20841847
Am J Med Sci. 2013 Apr;345(4):289-295
pubmed: 23531961
Curr Diab Rep. 2014 Jun;14(6):503
pubmed: 24792068
J Biomed Semantics. 2018 Feb 06;9(1):8
pubmed: 29409535