Effectiveness of the new generation transcatheter aortic valve in the real life studies. Review and meta-analysis.


Journal

European review for medical and pharmacological sciences
ISSN: 2284-0729
Titre abrégé: Eur Rev Med Pharmacol Sci
Pays: Italy
ID NLM: 9717360

Informations de publication

Date de publication:
Sep 2019
Historique:
entrez: 11 10 2019
pubmed: 11 10 2019
medline: 7 10 2020
Statut: ppublish

Résumé

The aim of the meta-analysis was to assess post-procedural outcome of the new generation of transcatheter aortic valve implantation (TAVI) devices, focusing on the transfemoral and balloon-expandable SAPIEN 3 (Edwards Lifesciences Inc., Irvine, CA, USA), the self-expanding CoreValveTM Evolut series R and PRO (R/PRO)TM (Medtronic Inc., Minneapolis, MN, USA) and ACURATE neoTM transcatheter aortic valve (Symetis SA, a Boston Scientific company, Ecublens, Switzerland). All observational studies were retrieved through PubMed computerized database from January 2014 until June 30th, 2019. The risk difference (RD) with the 95% confidence interval (CI) was used to assess the effectiveness of the intervention under comparison. The primary end point was 30-day mortality. Safety end points included: (i) stroke, (ii) moderate/severe paravalvular leak, and (iii) the need for new permanent pacemaker implantation. Meta-analysis demonstrated no significant differences as regards to either 30-day mortality or stroke for all the groups of prostheses under comparison. ACURATE neo was associated with significantly less new permanent pacemaker implantation compared to SAPIEN 3 (RD: -0.06; 95% CI -0.08 to -0.03; p<0.0001; I2=0%) or to EVOLUT R/PRO (RD: -0.06; 95% CI -0.09 to -0.02; p=0.0009; I2=0%). A significant reduction of new permanent pacemaker need was observed in the group of patients implanted with SAPIEN 3 compared to EVOLUT R/PRO (RD: -0.07; 95% CI -0.09 to -0.04; p<0.00001; I2=7%). The occurrence of moderate/severe leak was significantly increased in the group of patients implanted with ACURATE neo vs. SAPIEN 3 (RD: 0.04; 95% CI 0.02 to 0.05; p<0.00001; I2=0%). No significant differences were found between ACURATE neo vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.02; p=0.69; I2=0%) and between SAPIEN 3 vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.01; p=0.28; I2=73%). The results of the meta-analysis show that: (1) ACURATE neo was associated with significantly less new permanent pacemaker implantation than SAPIEN 3 and EVOLUT R/PRO; (2) SAPIEN 3 had significantly lower occurrence of moderate/severe valvular leak than ACURATE neo.

Identifiants

pubmed: 31599427
doi: 10.26355/eurrev_201909_19018
pii:
doi:

Types de publication

Journal Article Meta-Analysis Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

8018-8027

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH