Comparison of Semi-Automated Versus Manual Quantitative Right Ventricular Assessment in Hypoplastic Left Heart Syndrome.
EchoInsight
Echocardiography
Epsilon
Fractional area change
Hypoplastic left heart
Pediatric cardiology
Semi-automated analysis
Journal
Pediatric cardiology
ISSN: 1432-1971
Titre abrégé: Pediatr Cardiol
Pays: United States
ID NLM: 8003849
Informations de publication
Date de publication:
Jan 2020
Jan 2020
Historique:
received:
17
06
2019
accepted:
15
10
2019
pubmed:
30
10
2019
medline:
19
5
2020
entrez:
30
10
2019
Statut:
ppublish
Résumé
Quantitative echocardiographic evaluation is important for systemic right ventricles, but its asymmetric shape makes this challenging and time consuming when performed manually. Semi-automated software could make these quantitative measures easier to accomplish in the clinical setting. We hypothesized that semi-automated software would approximate manual measures of right ventricular size and function. Children with hypoplastic left heart who had echocardiograms were prospectively identified. These measurements were performed using manual and semi-automated techniques: end-diastolic and end-systolic area, fractional area change (FAC), dimensions (longitudinal, basal and mid-cavitary diameters), and tricuspid annular plane systolic excursion (TAPSE). Agreement between measures was evaluated. Sixty-three echocardiograms were analyzed. Intra- and inter-observer reliability was acceptable and similar between methods except that inter-observer reliability for the manual method was superior for TAPSE. Correlation between methods was high (r > 0.9, p < 0.001) for most of the measures. Correlation for FAC was r = 0.79, and for TAPSE the correlation was r = 0.61 (both p < 0.001). The percent relative difference between manual and semi-automated methods was less than 6% for most measures. End-systolic area and FAC had a relative difference of 10% and 11% respectively. The only measure with substantial bias between the manual and semi-automated methods was TAPSE which had a relative difference of 52%. EchoInsight® semi-automated software provides similar measures of right ventricular dimensions and FAC in patients with hypoplastic left heart compared to manual measures. Measures of TAPSE do not correlate well between manual and semi-automated methods. Further research is warranted on the use of semi-automated analyses in this patient population.
Identifiants
pubmed: 31659391
doi: 10.1007/s00246-019-02223-y
pii: 10.1007/s00246-019-02223-y
doi:
Types de publication
Comparative Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
69-76Références
Cardiol Young. 2001 Jul;11(4):399-406
pubmed: 11558949
Pediatr Cardiol. 2018 Mar;39(3):526-532
pubmed: 29184979
Int J Cardiovasc Imaging. 2015 Aug;31(6):1149-57
pubmed: 25948160
J Am Soc Echocardiogr. 2015 Aug;28(8):989-98
pubmed: 25857546
Eur J Echocardiogr. 2011 Sep;12(9):656-64
pubmed: 21810828
Pediatr Cardiol. 2018 Aug;39(6):1265-1275
pubmed: 29748699
Echocardiography. 2016 May;33(5):674-80
pubmed: 26751037
Am J Cardiol. 2000 Nov 1;86(9):964-8
pubmed: 11053708
J Am Soc Echocardiogr. 2006 Apr;19(4):391-402
pubmed: 16581478
Echocardiography. 2017 Apr;34(4):587-593
pubmed: 28191731
Cardiol Young. 2019 Sep;29(9):1149-1159
pubmed: 31412970
J Am Soc Echocardiogr. 2011 Jun;24(6):625-36
pubmed: 21392941
J Am Soc Echocardiogr. 2010 May;23(5):465-95; quiz 576-7
pubmed: 20451803
Echocardiography. 2015 Mar;32(3):528-34
pubmed: 25048993
World J Pediatr Congenit Heart Surg. 2018 Mar;9(2):171-176
pubmed: 29544412