On the Chromatic Dispersion of Hydrophobic and Hydrophilic Intraocular Lenses.


Journal

Optometry and vision science : official publication of the American Academy of Optometry
ISSN: 1538-9235
Titre abrégé: Optom Vis Sci
Pays: United States
ID NLM: 8904931

Informations de publication

Date de publication:
04 2020
Historique:
entrez: 19 4 2020
pubmed: 19 4 2020
medline: 20 3 2021
Statut: ppublish

Résumé

There is a high variation of chromatic dispersion with contemporary intraocular lens (IOL) materials. It is well known that chromatic aberration limits the optical performance especially with high-power lenses. Lens manufacturers, however, rarely provide data on the chromatic dispersion of their materials, limiting the comparability of available materials. This study aimed to analyze chromatic dispersion of hydrophobic and hydrophilic IOLs without prior knowledge of the IOLs' geometries. We adapted Bessel's method for measuring focal length by placing the IOL in a wet cell. The chromatic dispersion of several hydrophobic and hydrophilic IOLs was characterized by measuring their focal lengths at multiple wavelengths. From the measured focal lengths, the refractive indices and the Abbe numbers were obtained. We measured four hydrophobic and two hydrophilic IOL models with a nominal power of 21 to 29.5 D. The hydrophobic IOLs had lower Abbe numbers (Abbe numbers <41) than did the hydrophilic IOLs (Abbe numbers >50). Most Abbe numbers were in agreement with the values provided by the IOL manufacturers, and the measurements were independent from IOL power. The repeatability for the Abbe number was better than ±3.5% for all lenses and better than ±2% for lenses between 21 and 26.5 D. The dispersion could be described by a Conrady model (R > 0.997). The hydrophobic materials showed larger dispersion than did the hydrophilic IOL materials resulting in increased chromatic aberration. The method allowed for an estimation of the IOL's Abbe number without prior knowledge of IOL geometry.

Identifiants

pubmed: 32304541
doi: 10.1097/OPX.0000000000001495
pii: 00006324-202004000-00011
doi:

Substances chimiques

Biocompatible Materials 0

Types de publication

Journal Article Research Support, Non-U.S. Gov't Validation Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

305-313

Références

Doan KT, Olson RJ, Mamalis N. Survey of Intraocular Lens Material and Design. Curr Opin Ophthalmol 2002;13:24–9.
Campbell FW, Gubisch RW. The Effect of Chromatic Aberration on Visual Acuity. J Physiol (Lond) 1967;192:345–58.
Seidemann A, Schaeffel F. Effects of Longitudinal Chromatic Aberration on Accommodation and Emmetropization. Vision Res 2002;42:2409–17.
Graef K, Schaeffel F. Control of Accommodation by Longitudinal Chromatic Aberration and Blue Cones. J Vis 2012;12:1.
Nagata T, Kubota S, Watanabe I, et al. Chromatic Aberration in Pseudophakic Eyes. Nippon Ganka Gakkai Zasshi 1999;103:237–42.
Song H, Yuan X, Tang X. Effects of Intraocular Lenses with Different Diopters on Chromatic Aberrations in Human Eye Models. BMC Ophthalmol 2016;16:9.
Siedlecki D, Jóźwik A, Zając M, et al. In Vivo Longitudinal Chromatic Aberration of Pseudophakic Eyes. Optom Vis Sci 2014;91:240–6.
Pérez-Merino P, Dorronsoro C, Llorente L, et al. In Vivo Chromatic Aberration in Eyes Implanted with Intraocular Lenses. Invest Ophthalmol Vis Sci 2013;54:2654–61.
Vinas M, Gonzalez-Ramos A, Dorronsoro C, et al. In Vivo Measurement of Longitudinal Chromatic Aberration in Patients Implanted with Trifocal Diffractive Intraocular Lenses. J Refract Surg 2017;33:736–42.
Artal P, Manzanera S, Piers P, et al. Visual Effect of the Combined Correction of Spherical and Longitudinal Chromatic Aberrations. Opt Express 2010;18:1637–48.
Schwarz C, Cánovas C, Manzanera S, et al. Binocular Visual Acuity for the Correction of Spherical Aberration in Polychromatic and Monochromatic Light. J Vis 2014;14.
Weeber HA, Piers PA. Theoretical Performance of Intraocular Lenses Correcting Both Spherical and Chromatic Aberration. J Refract Surg 2012;28:48–52.
van Heel AC. Correcting the Spherical and Chromatic Aberrations of the Eye. J Opt Soc Am 1946;36:237–9.
Powell I. Lenses for Correcting Chromatic Aberration of the Eye. Appl Opt 1981;20:4152–5.
López-Gil N, Montés-Micó R. New Intraocular Lens for Achromatizing the Human Eye. J Cataract Refract Surg 2007;33:1296–302.
Fernandez EJ, Artal P. Achromatic Doublet Intraocular Lens for Full Aberration Correction. Biomed Opt Express 2017;8:2396–404.
Łabuz G, Papadatou E, Khoramnia R, et al. Longitudinal Chromatic Aberration and Polychromatic Image Quality Metrics of Intraocular Lenses. J Refract Surg 2018;34:832–8.
Franchini A. Compromise between Spherical and Chromatic Aberration and Depth of Focus in Aspheric Intraocular Lenses. J Cataract Refract Surg 2007;33:497–509.
Cauchy AL. New Math Exercises. Prague: J. G. Calve; 1836.
Smith WJ. Modern Optical Engineering. 2nd ed. New York: McGraw-Hill; 1990.
Atchison DA, Smith G. Chromatic Dispersions of the Ocular Media of Human Eyes. J Opt Soc Am (A) 2005;22:29–37.
Siedlecki D, Ginis HS. On the Longitudinal Chromatic Aberration of the Intraocular Lenses. Optom Vis Sci 2007;84:984–9.
Nakajima M, Hiraoka T, Yamamoto T, et al. Differences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers. PLoS One 2016;11:e0156227.
Conrady AE. Applied Optics and Optical Design. Part Two. New York: Dover Publications, Inc.; 1988.
Mikš A, Šmejkal M. Determination of the Refractive Index and Abbe Number of Glass of Spherical Lenses. Appl Opt 2018;57:4728–34.
Gissibl T, Wagner S, Sykora J, et al. Refractive Index Measurements of Photo-resists for Three-dimensional Direct Laser Writing. Opt Mater Express 2017;7:2293–8.
Kim SH, Lee SH, Lim JI, et al. Absolute Refractive Index Measurement Method over a Broad Wavelength Region Based on White-light Interferometry. Appl Opt 2010;49:910–4.
Pertuz S, Puig D, Garcia MA. Analysis of Focus Measure Operators for Shape-from-focus. Pattern Recog 2013;46:1415–32.
Pech-Pacheco JL, Cristobal G, Chamorro-Martinez J, et al. Diatom Autofocusing in Brightfield Microscopy: A Comparative Study. In: Proceedings of the 15th International Conference on Pattern Recognition. ICPR-2000: IEEE Comput Soc; September 3–7 2000:314–7.
Kannengießer M, Langenbucher A, Janunts E. Individual IOL Surface Topography Analysis by the WaveMaster Reflex UV. Biomed Res Int 2013;2013:363742.
Ernest PH. Light-transmission-spectrum Comparison of Foldable Intraocular Lenses. J Cataract Refract Surg 2004;30:1755–8.
Le Grand Y. Form and Space Vision, rev. ed. Bloomington, IN: Indiana University Press; 1967.
Langenbucher A, Schröder S, Cayless A, et al. Aberration-free Intraocular Lenses—What Does This Really Mean? Z Med Phys 2017;27:255–9.
Norrby S. Sources of Error in Intraocular Lens Power Calculation. J Cataract Refract Surg 2008;34:368–76.
Beadie G, Brindza M, Flynn RA, et al. Refractive Index Measurements of Poly(Methyl Methacrylate) (PMMA) from 0.4–1.6 μm. Appl Opt 2015;54:F139–43.
Haigis W. Pseudophakic Correction Factors for Optical Biometry. Graefes Arch Clin Exp Ophthalmol 2001;239:589–98.
Szczurowski M. Refractive Index of PMMA. Available at: https://refractiveindex.info/download/data/2013/Szczurowski%20-%20n_PMMA_raw.png. Accessed October 22, 2019.
Zhao H, Mainster MA. The Effect of Chromatic Dispersion on Pseudophakic Optical Performance. Br J Ophthalmol 2007;91:1225–9.
Piers PA, Weeber HA, Artal P, et al. Theoretical Comparison of Aberration-correcting Customized and Aspheric Intraocular Lenses. J Refract Surg 2007;23:374–84.
Guttman Krader C. Hydrophobic Acrylic IOL. EuroTimes 2011;16/17:18.
Steinbeis Transfer Zentrum Vision Research. IOLCon. International Database for Optimization of Intraocular Lens Constants. Available at: https://www.iolcon.org. Accessed November 10, 2018.
Speck A, Zelzer B, Kannengießer M, et al. Inspection of Freeform Intraocular Lens Topography by Phase Measuring Deflectometric Methods. Appl Opt 2013;52:4279–86.
Daimon M, Masumura A. Measurement of the Refractive Index of Distilled Water from the Near-infrared Region to the Ultraviolet Region. Appl Opt 2007;46:3811–20.
Li X, Liu L, Zhao J, et al. Optical Properties of Sodium Chloride Solution within the Spectral Range from 300 to 2500 nm at Room Temperature. Appl Spectrosc 2015;69:635–40.

Auteurs

Peter Hoffmann (P)

Augen- & Laserklinik Castrop Rauxel GmbH, Castrop-Rauxel, Germany.

Achim Langenbucher (A)

Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany.

Simon Schröder (S)

Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany.

Articles similaires

A molecular mechanism for bright color variation in parrots.

Roberto Arbore, Soraia Barbosa, Jindich Brejcha et al.
1.00
Animals Feathers Pigmentation Parrots Aldehyde Dehydrogenase

Personalized bioceramic grafts for craniomaxillofacial bone regeneration.

Ana Beatriz G de Carvalho, Maedeh Rahimnejad, Rodrigo L M S Oliveira et al.
1.00
Humans Bone Regeneration Ceramics Printing, Three-Dimensional Tissue Scaffolds

Aminoacid functionalised magnetite nanoparticles Fe

Spoială Angela, Motelica Ludmila, Ilie Cornelia-Ioana et al.
1.00
Magnetite Nanoparticles Tryptophan Biocompatible Materials Microbial Sensitivity Tests Humans
Animals Bone Morphogenetic Protein 2 Calcium Phosphates Rats Retrospective Studies

Classifications MeSH