A potential primary method for peptide purity analysis by gas chromatography-isotope dilution infrared spectrometry.
Amino acids
Gas chromatography-isotope dilution infrared spectroscopy
Purity
[Glu1]-fibrinopeptide B
Journal
Analytical and bioanalytical chemistry
ISSN: 1618-2650
Titre abrégé: Anal Bioanal Chem
Pays: Germany
ID NLM: 101134327
Informations de publication
Date de publication:
Aug 2023
Aug 2023
Historique:
received:
12
03
2023
accepted:
22
05
2023
revised:
12
05
2023
medline:
19
7
2023
pubmed:
9
6
2023
entrez:
8
6
2023
Statut:
ppublish
Résumé
Here we proposed a method for peptide purity analysis using gas chromatography-isotope dilution infrared spectroscopy. The principle and feasibility of the proposed measurement method were investigated. The derivatization, separation, and infrared detection conditions for amino acids were optimized, and the performance of the method was investigated. Then, the proposed method was used for assessment of [Glu
Identifiants
pubmed: 37291250
doi: 10.1007/s00216-023-04772-x
pii: 10.1007/s00216-023-04772-x
doi:
Substances chimiques
Isotopes
0
Peptides
0
Amino Acids
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
4795-4804Subventions
Organisme : NIM internal funding
ID : AKYZD1907-1
Informations de copyright
© 2023. Springer-Verlag GmbH Germany, part of Springer Nature.
Références
Lee H, Lee J, Park S, et al. Development and validation of primary method for the determination of glucose in human serum by isotope dilution liquid chromatography tandem mass spectrometry and comparison with field methods. Bull Korean Chem Soc. 2013;34(6):1698–702.
doi: 10.5012/bkcs.2013.34.6.1698
Luo Y, Wu L, Yang B, et al. A novel potential primary method for quantification of enantiomers by high performance liquid chromatography-circular dichroism. Sci Rep. 2018;8:11.
Sturgeon R, Methven B, Willie S, et al. Assignment of purity to primary metal calibrants using pin-cell VG 9000 glow discharge mass spectrometry: a primary method with direct traceability to the SI international system of units? Metrologia. 2014;51(5):410–22.
doi: 10.1088/0026-1394/51/5/410
Taylor P, Kipphardt H, De Bièvre P. The definition of primary method of measurement (PMM) of the ‘highest metrological quality’: a challenge in understanding and communication. Accred Qual Assur. 2011;6:103–6.
doi: 10.1007/PL00010444
Quinn T. Primary methods of measurement and primary standards. Metrologia. 1997;34(1):61.
doi: 10.1088/0026-1394/34/1/9
Rampler E, Criscuolo A, Zeller M, et al. A novel lipidomics workflow for improved human plasma identification and quantification using RPLC-MSn methods and isotope dilution strategies. Anal Chem. 2018;90(11):6494–501.
doi: 10.1021/acs.analchem.7b05382
pubmed: 29708737
Solano M, Woolfitt A, Williams T, et al. Quantification of influenza neuraminidase activity by ultra-high performance liquid chromatography and isotope dilution mass spectrometry. Anal Chem. 2017;89(5):3130–7.
doi: 10.1021/acs.analchem.6b04902
pubmed: 28192976
pmcid: 5695552
Botelho J, Ribera A, Cooper H, et al. Evaluation of an isotope dilution HPLC tandem mass spectrometry candidate reference measurement procedure for total 17-beta estradiol in human serum. Anal Chem. 2016;88(22):11123–9.
doi: 10.1021/acs.analchem.6b03220
pubmed: 27744701
pmcid: 5709807
Dong L, Meng Y, Wang J, et al. Evaluation of droplet digital PCR for characterizing plasmid reference material used for quantifying ammonia oxidizers and denitrifiers. Anal Bioanal Chem. 2014;406:1701–12.
doi: 10.1007/s00216-013-7546-1
pubmed: 24493332
pmcid: 3936116
Scanlan L, Coskun S, Pet Jaruga, et al. Measurement of oxidatively induced DNA damage in Caenorhabditis elegans with high-salt DNA extraction and isotope-dilution mass spectrometry. Anal Chem. 2019;91(19):12149–55.
doi: 10.1021/acs.analchem.9b01503
pubmed: 31454479
pmcid: 6996937
Deng Y, Zhao H, Liu Q, et al. The potential for isotope dilution-LC-MS/MS to improve laboratory measurement of C-peptide: reasons and critical determinants. J Mass Spectrom and Adv Clin Lab. 2021;21:1–9.
doi: 10.1016/j.jmsacl.2021.07.001
Pierce-Ruiz C, Santana W, Sutton W, et al. Quantification of SARS-CoV-2 spike and nucleocapsid proteins using isotope dilution tandem mass spectrometry. Vaccine. 2021;39(36):5106–15.
doi: 10.1016/j.vaccine.2021.07.066
pubmed: 34344552
pmcid: 8302847
Zakel S, et al. Validation of isotope dilution surface-enhanced Raman scattering (IDSERS) as a higher order reference method for clinical measurands employing international comparison schemes. J Raman Spectrosc. 2013;44(9):1246–52.
doi: 10.1002/jrs.4349
Yaghobian F, Stosch R, Güttler B. Quantification of peptides based on isotope dilution surface enhanced Raman scattering. Int Scholar Sci Res Innov. 2012;6(3):2012.
Wang X, Wu L, Huang Y, et al. Development of a human insulin certified reference material with SI-traceable purity. Anal Bioanal Chem. 2022;414(11):3443–57.
doi: 10.1007/s00216-022-03965-0
pubmed: 35201368
Barbara H. Stuart Infrared Spectroscopy: Fundamentals and Applications. West Sussex: John Wiley & Sons; 2004.
Edwin S, John W, Froehlich ML. Determination of carboxylic acids by isotope dilution gas chromatography/Fourier transform infrared spectroscopy. Anal Chem. 1988;60:1920–4.
doi: 10.1021/ac00169a016
Moran S, Zanni M. How to get insight into amyloid structure and formation from infrared spectroscopy. J Phys Chem Lett. 2014;5(11):1984–93.
doi: 10.1021/jz500794d
pubmed: 24932380
pmcid: 4051309
Saxena V, Steendam R, Jansen T. Distinguishing islet amyloid polypeptide fibril structures with infrared isotope-label spectroscopy. J Chem Phys. 2022;156(5):055101–11. https://doi.org/10.1063/5.0082322 .
doi: 10.1063/5.0082322
pubmed: 35135274
Martin-Gomez P, Barbeta A, Voltas J, et al. Isotope-ratio infrared spectroscopy: a reliable tool for the investigation of plant-water sources? New Phytol. 2015;207(3):914–27.
doi: 10.1111/nph.13376
pubmed: 25790288
Viallon J, Flores E, Moussay P, et al. An optimized sampling system for highly reproducible isotope ratio measurements (delta C-13 and delta O-18) of pure CO(2)gas by infrared spectroscopy. Metrologia. 2020;57(5):055004–9. https://doi.org/10.1088/1681-7575/ab948c .
doi: 10.1088/1681-7575/ab948c
Hirano S, Kanamatsu T, Takagi Y, et al. A simple infrared spectroscopic method for the measurement of expired
doi: 10.1016/0003-2697(79)90554-2
pubmed: 495993
Irving C, Klein P, Navratil P, et al. Measurement of
doi: 10.1021/ac00124a014
pubmed: 3094401
Schröder D, Schwarz H, Milko P, et al. Dissociation routes of protonated toluene probed by infrared spectroscopy in the Gas phase. J Phys Chem A. 2006;110:8346–53.
doi: 10.1021/jp056962f
pubmed: 16821818
Civiš S, Ferus M, Zukalová M, et al. The application of high-resolution IR spectroscopy and isotope labeling for detailed investigation of TiO
doi: 10.1016/j.optmat.2013.04.009
Vreugdenhil A, Stephane H, Ross D, et al. Headspace analysis gas-phase infrared spectroscopy: a study of xanthate decomposition on mineral surfaces. J Mol Struct. 1997;405:67–77.
doi: 10.1016/S0022-2860(96)09449-5
Rochkind MM. Quantitative infrared analysis of mixtures of isotopically labelled gases. Anal Chem. 1967;39:567.
doi: 10.1021/ac60250a036
Gray C, Compagnon I, Flitsch S. Mass spectrometry hybridized with gas-phase InfraRed spectroscopy for glycan sequencing. Struct Biol. 2020;62:121–31.
Mossoba M, Niemann R, Jo-Yun T. Picogram level quantitation of 2,3,7,8-tetrachlorodibenzo-p-dioxin in fish extracts by capillary gas chromatography/matrix isolation/Fourier transform infrared spectrometry. Anal Chem. 1989;61:1678–85.
doi: 10.1021/ac00190a019
pubmed: 2774196
Gaussian 16, Revision C.01, Frisch M, Trucks G, Schlege H, Scuseria G, Robb M, Cheeseman J, Scalmani G, Barone V, Petersson G, Nakatsuji H, Li X, Caricato M, Marenich A, Bloino J, Janesko B, Gomperts R, Mennucci B, Hratchian H, Ortiz J, Izmaylov A, Sonnenberg J, Williams-Young D, Ding F, Lipparini F,Egidi F, Goings J, Peng B, Petrone A, Henderson T, Ranasinghe D, Zakrzewski V, Gao J, Rega N, Zheng G, Liang W, Hada M, Ehara M, Toyota K, Fukuda R, Hasegawa J, Ishida M, Nakajima T, Honda Y, Kitao O, Nakai H, Vreven T, Throssell K, Montgomery, Jr A, Peralta J, Ogliaro F, Bearpark M, Heyd J, Brothers E, Kudin K, Staroverov V, Keith T, Kobayashi R, Normand J, Raghavachari K, Rendell A, Burant J, Iyengar S, Tomasi J, Cossi M, Millam J, Klene M, Adamo C, Cammi R, Ochterski J, Martin R, Morokuma K,Farkas O, ForesmanJ, Fox D,Gaussian Inc, Wallingford C, 2019.
Dai X, Fang X, Zhang C, et al. Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method. J Chromatogr B. 2007;857:287–95.
doi: 10.1016/j.jchromb.2007.07.035