Institute of Chemical Biology and Fundamental Medicine, SD of Russian Academy of Sciences, 8 Lavrentiev Ave., Novosibirsk 630090, Russia. Electronic address: nevinsky@niboch.nsc.ru.
Publications dans "Immunoglobuline A sécrétoire" :
Institute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences, 8 Lavrentiev Ave., Novosibirsk 630090, Russia.
Publications dans "Immunoglobuline A sécrétoire" :
G. B. Elyakov Pacific Institute of Bioorganic Chemistry, Far Eastern Branch of the Russian Academy of Sciences, 159 Pr. 100 let Vladivostoku, Vladivostok 690022, Russia.
Publications dans "Immunoglobuline A sécrétoire" :
Department of Evolutionary Biology, Ecology and Environmental Sciences, University of Barcelona, Spain; Network Centre for Biomedical Research in Mental Health (CIBER of Mental Health, CIBERSAM), Institute of Health Carlos III, Spain; Institute of Biomedicine of the University of Barcelona (IBUB), Barcelona, Spain.
Publications dans "Immunoglobuline A sécrétoire" :
Network Centre for Biomedical Research in Mental Health (CIBER of Mental Health, CIBERSAM), Institute of Health Carlos III, Spain; Department of Epidemiology, University of Florida, United States.
Publications dans "Immunoglobuline A sécrétoire" :
Department of Evolutionary Biology, Ecology and Environmental Sciences, University of Barcelona, Spain; Network Centre for Biomedical Research in Mental Health (CIBER of Mental Health, CIBERSAM), Institute of Health Carlos III, Spain; Institute of Biomedicine of the University of Barcelona (IBUB), Barcelona, Spain. Electronic address: lfananas@ub.edu.
Publications dans "Immunoglobuline A sécrétoire" :
Cell Biology Program, The Hospital for Sick Children, PGCRL Building, Room 15.9716, 686 Bay Street, Toronto, Ontario, M5G 0A4, Canada; Institute of Medical Science, University of Toronto, Medical Sciences Building, Room 2374, 1 King's College Circle, Toronto, Ontario, M5S 1A8, Canada; Department of Molecular Genetics, University of Toronto, Medical Sciences Building, Room 4396, 1 King's College Circle, Toronto, Ontario, M5S 1A8, Canada. Electronic address: julie.brill@sickkids.ca.
Publications dans "Immunoglobuline A sécrétoire" :
Stem Cell Biology Group, Waghmare Lab, Cancer Research Institute, Advanced Centre for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, Kharghar, Navi Mumbai, 410210, Maharashtra, India; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai, 400085, India.
Publications dans "Immunoglobuline A sécrétoire" :
Troponin elevation is frequently observed in various scenarios in the Emergency Department (ED), yet there is a paucity of studies investigating simultaneously measured high-sensitivity cardiac tropon...
All patients who underwent troponin testing at a single center were eligible for this study. Only patients with simultaneous samples with hs-cTnI (Siemens) and hs-cTnT (Roche) were included, regardles...
Analysis of 1987 samples from 1134 patients showed a significant correlation between hs-cTnT and hs-cTnI (r = 0.86, p < 0.01). Of these samples, 65% exceeded the upper reference limit (URL) for hs-cTn...
Elevated troponins above the URL were very common in this diverse cohort, particularly for hs-cTnT, which was twice as frequent compared to hs-cTnI, resulting in low specificity and PPV for AMI....
We examined the diagnostic performance of a recalibrated History, Electrocardiogram, Age, Risk factors, Troponin (HEART), and Thrombolysis in Myocardial Infarction (TIMI) score in patients with suspec...
We undertook a 2-center prospective cohort study in the United Kingdom (UK) (2018) (Clinicaltrials.gov NCT03619733) to specifically assess recalibrated risk scores (shifting the troponin subset scorin...
We studied 3,752 patients (3,003 in the UK and 749 in the United States). Median age was 58 years, and 48% were female. At 30 days, 330/3,752 (8.8%) experienced MACE. The sensitivities of the original...
This study indicates that recalibrated HEART score of less or equal to 3 is a feasible and safe early discharge strategy using a single presentation hs-cTnT. This finding should be further tested usin...
The HEART Pathway is widely used for chest pain risk stratification but has yet to be optimized for high sensitivity troponin T (hs-cTnT) assays....
We conducted a secondary analysis of STOP-CP, a prospective cohort study enrolling adult ED patients with symptoms suggestive of acute coronary syndrome at 8 sites in the United States (US). Patients ...
Among the 1452 patients, 30-day cardiac death or MI occurred in 12.7% (184/1452). Within the derivation cohort the optimal hs-cTnT HEART Pathway classified 36.5% (266/729) into the rule-out group, yie...
A novel hs-cTnT HEART Pathway with serial 0- and 1-hour hs-cTnT measures has high NPV and moderate PPV for 30-day cardiac death or MI....
The diagnosis of acute myocardial infarction (AMI), especially within the first hours after onset of ischemia, poses a challenge to the forensic pathologist. During this time, the infarction is genera...
Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimin...
We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99th percentile at 2 hours from pr...
The median hs-cTn I/T ratio was 3.45 (25th, 75th percentiles 1.80-6.59) in type 1 MI patients (n = 408 ☯46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 ☯6.3%]) and 0.67 (0.39-1.12) in patients...
The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio...
Blood measurement of cardiac troponin T (cTnT) is one of the most widespread methods of acute myocardial infarction (MI) diagnosis. cTnT degradation may have a significant influence on the precision o...
Serial heparin plasma samples were collected from 37 MI patients 2-37 h following the onset of MI. cTnT and its fragments were studied by western blotting and immunofluorescence analysis using monoclo...
cTnT was present in the blood of MI patients as 23 proteolytic fragments with an apparent molecular mass of ∼ 8-37 kDa. Two major sites of cTnT degradation were identified: between amino acid residues...
cTnT progressively degrades after MI and appears in the blood as a mixture of 23 proteolytic fragments. The cTnT region approximately bordered by aar 69-158 is a promising target for antibodies used f...
Background The prognostic implications of temporal change of previously stable high-sensitivity cardiac troponin concentrations are unknown. We investigated the prognosis associated with temporal chan...
Though false elevations attributed to preanalytical specimen handling have been widely reported for Troponin I (TnI), Troponin T (TnT) has appeared more robust to falsely elevated Tn. We describe repr...
This study is aimed at testing the hypothesis that serum analysis of high-sensitivity troponin T in neonates may serve as a diagnostic tool to predict the risk of gestational diabetes mellitus (GDM). ...
Troponin assays are used in the diagnosis of myocardial injury and may show elevated results for a variety of reasons. However it is increasingly recognised that cardiac troponin elevation may in some...
We identified patients presenting to two local emergency departments over a five-day period who had chsTnT levels measured as part of routine clinical care. All samples with elevated chsTnT levels (ab...
A total of 74 samples from 54 patients were analysed for chsTnT and chsTnI. 7 samples (9.5%) had chsTnI levels < 5 ng/L suggesting assay interference as the cause of chsTnT elevation....
Assay interference leading to false positive troponin elevation may be more common than many physicians appreciate and can potentially lead to harmful investigation and treatment for patients. In case...