Grup de Productes Naturals, Departament de Biologia, Sanitat i Medi Ambient, Facultat de Farmàcia i Ciències de l'Alimentació, Universitat de Barcelona, Av. Joan XXIII, 27-31, Barcelona 08028, Spain.
South African journal of botany : official journal of the South African Association of Botanists = Suid-Afrikaanse tydskrif vir plantkunde : amptelike tydskrif van die Suid-Afrikaanse Genootskap van Plantkundiges
2020-09-18
Institute for Plant Biology, Technische Universität Braunschweig, Mendelssohnsstr. 4, 38106, Braunschweig, Germany. Electronic address: d.selmar@tu-bs.de.
ADINACO Research Group, Department of Pharmaceutical Botany, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic; Department of Pharmacognosy, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic.
Department of Toxicology and Military Pharmacy, Trebesska 1575, 500 05, Hradec Kralove, Czech Republic; Biomedical Research Centre, University Hospital Hradec Kralove, Sokolska 581, 500 05, Hradec Kralove, Czech Republic.
ADINACO Research Group, Department of Pharmaceutical Botany, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic.
ADINACO Research Group, Department of Pharmaceutical Botany, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic.
ADINACO Research Group, Department of Pharmaceutical Botany, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic.
ADINACO Research Group, Department of Pharmaceutical Botany, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic. Electronic address: cahlikova@faf.cuni.cz.
To review the recent evidence in the literature regarding the efficacy and safety of gonioscopy-assisted transluminal trabeculotomy (GATT) in the management of pediatric and adult glaucoma....
A literature search was performed in the electronic databases of PubMed, Google Scholar, Embase the Register of Controlled Trials, and Ovid Medline for studies evaluating the safety and outcomes of GA...
GATT is a novel minimally invasive glaucoma surgery that allows the incision of the inner wall of Schlemm's canal increasing aqueous drainage through the physiologic outflow pathway with subsequent in...
GATT demonstrated favorable results in a wide range of both primary and secondary open-angle and angle-closure glaucoma....
To compare the efficacy and invasiveness of manual gonioscopy and automated 360-degree gonioscopy....
Manual and automated gonioscopy were performed on 70 patients with glaucoma. Manual gonioscopy was performed by a glaucoma specialist and an ophthalmology resident, and automated gonioscopy (GS-1) was...
The examination time was not significantly different between manual (80.2±28.7) and automated gonioscopy (94.7±82.8) (p = 0.105). The pain score of automated gonioscopy (0.22±0.59) was significantly l...
Automated gonioscopy is comparable in examination time and invasiveness to manual gonioscopy and may be useful for 360-degree iridocorneal angle evaluation....
To evaluate the effect of Gonioscopy-assisted transluminal trabeculotomy (GATT) on macular thickness and to compare the combined GATT and cataract extraction (CE) with GATT surgery alone regarding mac...
A retrospective, comparative study was designed. The patients who underwent GATT or combined GATT and CE with preoperative and regular postoperative spectral domain optic coherence tomography analysis...
Fifty-four eyes fulfilled the inclusion criteria and were enrolled in this study, (Group 1 = 29 eyes, Group 2 = 25 eyes). The mean thicknesses of central macula (CM), superior inner macula (SIM), and ...
GATT can be a safe procedure with minimal and transient adverse effect on macular thickness and structure. Performing GATT together with CE caused no additional increase in the risk of macular thicken...
Automated gonioscopy provided good-quality images of the anterior chamber angle. There was a short learning curve for operators, and the examination was well tolerated by patients. Patients expressed ...
The purpose of this study was to assess the feasibility of using a desktop automated gonioscopy camera in glaucoma clinics by examining patient tolerability, ease of use, and image quality and compari...
A prospective study was conducted in a university hospital clinic. Traditional gonioscopy was performed followed by imaging of the iridocorneal angle (ICA) using the Nidek GS-1 camera by 2 glaucoma sp...
Forty-three eyes of 25 participants were included. Sixty-eight percent of participants viewed automated gonioscopy as "extremely comfortable," and the remainder reported it "comfortable". Forty percen...
Automated gonioscopy provided good-quality images of the ICA for most patients. It was often not possible to image the entire 360 degrees at the first attempt, but the examination was comfortable for ...
A 69-year-old male patient with Pseudoexfoliation and open angle glaucoma presented with malignant glaucoma 1 week after undergoing gonioscopy-assisted transluminal trabeculotomy (GATT). This is a rar...
We describe 4 cases of eyes initially treated with phacoemulsification and iStent trabecular microbypass (Glaukos Corporation). These patients subsequently required further surgery and were successful...
GATT can be performed efficaciously and safely by PGY-3 and PGY-4 residents, with clinical outcomes and complication rates that mirror those of attending-performed GATT cohorts from the literature....
Report outcomes of gonioscopy-assisted transluminal trabeculotomy (GATT) performed by PGY-3 and PGY-4 residents....
A retrospective chart review was performed for patients undergoing resident-performed GATT. Eyes with previous traditional glaucoma surgery (trabeculectomy or aqueous shunt) or neovascular glaucoma we...
A total of 50 eyes from 40 patients with various types of glaucoma were included. Eyes either underwent resident-performed GATT-alone (N=9) or GATT+cataract extraction with intraocular lens implantati...
GATT can be performed efficaciously and safely by PGY-3 and PGY-4 residents, with clinical outcomes and complication rates that mirror those of attending-performed GATT cohorts from the literature....
To evaluate the outcomes of gonioscopy-assisted transluminal trabeculotomy (GATT) in adult eyes with uncontrolled uveitic glaucoma....
We reviewed 16 eyes from 13 patients. Surgical success was defined as intraocular pressure (IOP) reduction >20% from baseline or IOP between 5 and 21 mmHg by the 3-month visit while on a stable number...
At 12 months, the cumulative success rate was 81%. Mean IOP was 37.8 ± 13.0 mmHg at baseline and 12.2 ± 3.0 mmHg at 12 months (68% reduction;...
This small retrospective study suggests that GATT is effective and safe as an initial surgical treatment for medically refractory glaucoma in uveitic adult eyes....
To systematically review surgical procedure, safety and efficacy of Gonioscopy-Assisted Transluminal Trabeculotomy (GATT)....
A review of literature was done to analyze all suitable articles from two different databases....
GATT is effective in reducing intraocular pressure and mean number of medications from baseline. It is associated with minimal complications when compared to ab-externo procedures. It has shorter lear...
GATT is a minimally invasive surgical procedure for the management of primary and secondary open-angle glaucoma in both adults and children. The advantages of GATT are ab-interno approach, access to o...
Human corneoscleral rims provide a low cost model and resource to enhance angle based glaucoma surgical training skills....
To understand the feasibility, utility, and efficacy of a low-cost model for performing anterior chamber angle gonioscopy and micro-surgery on human corneoscleral tissues in wet lab on resident skill ...
Post-keratoplasty residual corneoscleral rims and/or the expired donor corneoscleral buttons were included for the purpose of this study. Initially, inverted rims were used to demonstrate the basic an...
A total of 65 residents were included in the exercise. The mean age was 26.69±1.74 years. Amongst these, 55 ophthalmology residents performed the basic examination, that is, slit lamp mounted angle an...
The residual human corneoscleral rims proved to be an important resource for teaching both the basic examination skills and those required for transitioning to advanced intraoperative gonioscopy and g...