Department of Molecular Neuroimmune Signaling, Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry, Russian Academy of Sciences, Moscow, Russia (D.S.L., E.V.K., I.A.I., N.S.E., N.D.T., E.N.S., E.Y.T., A.E.S., D.S.K., I.E.K., V.I.T.); Department of Neurobiology, Hellenic Pasteur Institute, Athens, Greece (M.Z., S.J.T.); Institute of Molecular Medicine, Sechenov First Moscow State Medical University, Moscow, Russia (I.E.K.); Institute of Chemistry and Molecular Engineering, Agricultural University of Georgia, Kakha Bendukidze University Campus, Tbilisi, Georgia (R.K., N.Z., I.I.); and PhysBio of MePhI, Moscow, Russia (V.I.T.) victortsetlin3f@gmail.com.
Publications dans "Inhibiteurs de la libération d'acétylcholine" :
b Beijing Key Laboratory of Drug Clinical Risk and Personalized Medication Evaluation, Department of Clinical Pharmacology , Beijing Hospital , Bejing 100044 , China.
Publications dans "Inhibiteurs de la libération d'acétylcholine" :
Single-use flexible bronchoscopes(SFB) eliminate the risk of bronchoscopy-related infection compared with traditional reusable flexible bronchoscopes(RFB). At present, there is no comparative study be...
We conducted a prospective controlled study. A total of 45 patients who required bronchoscopic biopsy in our hospital from June 2022 to December 2022 were enrolled. The patients were divided into the ...
The routine examination time of SFB and RFB was 3.40 ± 0.50 min and 3.55 ± 0.42 min, respectively. There was no significant difference between the two groups (P = 0.308). The recovery rate of BALF was...
SFBs are non-inferior to RFBs in routine bronchoscopy, bronchoalveolar lavage, and biopsy. It is suggested that SFBs have a wider clinical application....
Transbronchial lung cryobiopsy is useful when diagnosing lung lesions. However, prevention of associated bleeding complications is essential. This study aimed to evaluate the safety and efficacy of ou...
Patients with localized or diffuse lung lesions were prospectively enrolled and underwent cryobiopsy using a 1.9 mm diameter cryoprobe and a 4.0 mm diameter thin bronchoscope under conscious sedation....
Of the 80 patients initially enrolled, 73 that underwent at least one cryobiopsy were ultimately included. Mild bleeding during cryobiopsy occurred in 58 patients (79.5%), but there was no moderate or...
Thin bronchoscopic cryobiopsy using a nasobronchial tube in consciously sedated patients is safe and effective. Trial registration Date of registration: 24/06/2019. UMIN-Clinical Trials Registry; Iden...
Ultrathin bronchoscopy aids in the diagnosis of peripheral pulmonary lesions. However, both the working channel and the specimens are small. A 1.1-mm ultrathin cryoprobe that can enter the working cha...
Patients with peripheral pulmonary lesions ≤30 mm in diameter were prospectively enrolled in the study. All patients underwent forceps biopsy followed by cryobiopsy using a 3.0-mm ultrathin bronchosco...
In total, 50 patients with peripheral pulmonary lesions were enrolled in the study; the median longest diameter on computed tomography was 17.9 mm. Cryobiopsy was performed successfully in 49 patients...
Ultrathin bronchoscopic cryobiopsy is feasible, effective and sufficiently safe for the diagnosis of peripheral pulmonary lesions....
In the past few decades, the inadequate reprocessing of bronchoscopes has been associated with several serious outbreaks caused by multidrug-resistant microorganisms. In this study we evaluated the im...
In 2019, observational and clinical audits were conducted in the BU. After the introduction of an improved procedure in 2020, a microbiological surveillance plan was implemented in 2021....
In 2019, 13 of 22 bronchoscopes (59%) resulted as non-compliant, 18% as high concern organisms (HCO) and 36.4% as high microbial count (≥100 CFU/all channels) and HCO. The most frequent microorganisms...
The adoption of an improved reprocessing procedure decreased the non-compliance of bronchoscopes, increasing the quality of the process and patient safety....
Endobronchial ultrasound (EBUS) bronchoscopes have been used mainly through the airway for EBUS-guided transbronchial needle aspiration (EBUS-TBNA); however, they can also be used through the esophagu...
This study aimed to evaluate the value of adding EUS-B-FNA to EBUS-TBNA performed by pulmonologists for intrathoracic lesions in the clinical setting....
Between March 2009 and March 2020, all patients who underwent EUS-B-FNA and EBUS-TBNA for diagnostic purposes were included and retrospectively analyzed at a single institution....
A total of 1794 procedures using an EBUS bronchoscope including, EBUS-TBNA, EUS-B-FNA, and the combination of EBUS-TBNA and EUS-B-FNA for evaluating intrathoracic lesions, were performed. We finally a...
Pulmonologists are able to enhance diagnostic yields by acquiring the EUS-B-FNA technique....
Fiberoptic bronchoscopy (FOB) and bronchoscopic biopsy are the established methods for diagnosing and treating sputum crust. However, sputum crust in concealed locations can sometimes be missed or und...
We present the case of a 44-year-old female patient who experienced initial extubation failure and postoperative pulmonary complications (PPCs) due to the missed diagnosis of sputum crust by FOB and l...
FOB examination may miss specific areas in endotracheal intubation (ETI) patients, particularly the tracheal wall between the subglottis and distal end of the tracheal catheter, where sputum crust can...
Direct insertion of a double-lumen tube (DLT) using a flexible fiberoptic bronchoscope (FOB) is an option for DLT intubation. The difficult process of fiberoptic intubation is that the different prope...
Patients aged 19-75 years who required one-lung ventilation under general anesthesia were enrolled in this study. After induction of anesthesia, the anesthesiologist intubated the DLT using FOB. The p...
A total of 46 patients participated in this study, 23 each in the silicone and polyvinyl groups. The difficulty of railroading over the FOB was significantly different between the two groups (P < 0.00...
Intubation using a silicone DLT over an FOB was easier and faster than that with a polyvinyl chloride DLT with lesser trauma around the glottis....
Along with the wide spread application and technical development of the flexible and rigid bronchoscopy, the airway foreign body removing method cme to the specific technique for different foreign bod...
Selected 633 children who were diagnosed as airway foreign bodies by the Department of Respiratory Intervention, Children's Hospital affiliated to Shandong University from January 1st, 2018 to Decembe...
The success rate using flexible bronchoscope alone to remove foreign bodies in the airway was 99.2%. After flexible bronchoscopy, 19 cases of foreign bodies were removed by vacuum suction alone, 513 c...
According to different properties of airway foreign bodies, it is safe and effective to select appropriate techniques to remove foreign bodies using the flexible bronchoscope, which can increase the r...
Flexible bronchoscopes are increasingly being used in diagnostic and therapeutic medicine and have obviated the need for and risks associated with general anesthesia. Here the authors present the case...
Endotracheal intubation with a flexible bronchoscope is a well-recognized airway management technique that anesthesiologists must master. Skill acquisition and knowledge must reach an appropriate leve...
This study included 12 first-year anesthesiology residents with no previous experience with flexible bronchoscopic intubation. Trainees attended theoretical and simulation training and performed flexi...
Trainees performed flexible bronchoscope-guided orotracheal intubation on 364 patients. First-attempt intubation success occurred in 317 (87.1%) patients. Second-attempt intubation success occurred in...
Learning curves constructed with CUSUM analysis showed that all trainees (anesthesiologist residents) included in this study achieved competence (intubation success rates ≥ 80%) in flexible bronchosco...
Trial registration: Chinese Clinical Trial Register, ChiCTR 2000032166....