Optimization of vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction for quantification of niclosamide in real samples.

Box–Behnken design Complex matrices Hydrophobic magnetic deep eutectic solvent Niclosamide Spectrophotometry

Journal

Food chemistry
ISSN: 1873-7072
Titre abrégé: Food Chem
Pays: England
ID NLM: 7702639

Informations de publication

Date de publication:
15 Nov 2023
Historique:
received: 17 03 2023
revised: 26 05 2023
accepted: 14 06 2023
medline: 19 7 2023
pubmed: 26 6 2023
entrez: 25 6 2023
Statut: ppublish

Résumé

In this manuscript, a green and fast vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction (VA-HMDES-DLPME) method was developed for the selective extraction and determination of niclosamide in read samples, including rice, medicine tablets, and water samples. Here, hydrophobic magnetic deep eutectic solvents were used as the extracting solvent without requiring any centrifugation step. In the light of preliminary experiments, important parameters, such as volume of extraction solvent, pH, acetonitrile volume and vortex time, affecting the extraction efficiency of niclosamide were optimized using a Box-Behnken design. The linear dynamic range (0.25-120 µg/L), the limit of detection (0.08 µg/L), the limit of quantitation (0.25 µg/L), preconcentration factor (180), and enrichment factor (130) of the method were determined using optimized data. In particular, the validation parameters of the optimized VA-HMDES-DLPME, including robustness, matrix effect accuracy, and precision, were investigated. In addition to this, intra- and inter-day precisions were determined as ≤3.5 % and ≤4.1%, respectively. Finally, the optimized method was successfully used for the extraction of niclosamide in the selected samples prior to spectrophotometric analysis.

Identifiants

pubmed: 37356246
pii: S0308-8146(23)01264-5
doi: 10.1016/j.foodchem.2023.136646
pii:
doi:

Substances chimiques

Solvents 0
Niclosamide 8KK8CQ2K8G
Deep Eutectic Solvents 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

136646

Informations de copyright

Copyright © 2023 Elsevier Ltd. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Nail Altunay (N)

Faculty of Science, Department of Chemistry, Sivas Cumhuriyet University, Sivas, Türkiye. Electronic address: naltunay@cumhuriyet.edu.tr.

Hameed Ul Haq (H)

Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Sanitary Engineering, G. Narutowicza St. 11/12, Gdansk 80 - 233, Poland.

Roberto Castro-Muñoz (R)

Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Sanitary Engineering, G. Narutowicza St. 11/12, Gdansk 80 - 233, Poland.

Articles similaires

Perylene Dopamine Electrochemical Techniques Imides Luminescent Measurements
Colorimetry Captopril Humans Alloys Limit of Detection

Low-cost portable sensor for rapid and sensitive detection of Pb

Niloufar Amin, Jiangang Chen, Qing Cao et al.
1.00
Lead Electric Capacitance Limit of Detection Electrodes Electrochemical Techniques
Aluminum Carbon Quantum Dots Spectrometry, Fluorescence Limit of Detection

Classifications MeSH