Departamento de Ciencias Básicas de la Salud, Facultad de Ciencias de la Salud, Universidad Rey Juan Carlos, Alcorcón, Spain.
Unidad Asociada al Instituto de Química Medica (IQM) del Consejo Superior de Investigaciones Científicas (CSIC), Universidad Rey Juan Carlos, Alcorcón, Spain.
High Performance Research Group in Experimental Pharmacology (Pharmakom-URJC), URJC, Alcorcón, Spain.
Departamento de Ciencias Básicas de la Salud, Facultad de Ciencias de la Salud, Universidad Rey Juan Carlos, Alcorcón, Spain.
Unidad Asociada al Instituto de Química Medica (IQM) del Consejo Superior de Investigaciones Científicas (CSIC), Universidad Rey Juan Carlos, Alcorcón, Spain.
High Performance Research Group in Experimental Pharmacology (Pharmakom-URJC), URJC, Alcorcón, Spain.
Department of Psychiatry, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, China; Mental Health Institute of the Second Xiangya Hospital, Central South University, Chinese National Clinical Research Center on Mental Disorders (xiangya), Chinese National Technology Institute on Mental Disorders, Hunan Key Laboratory of Psychiatry and Mental Health, Changsha, Hunan 410011, China.
The active transcutaneous bone conduction implant (tBCI; BONEBRIDGE™ BCI 601; MED-EL, Innsbruck, Austria) is fixed to the skull with two self-tapping screws in predrilled screw channels. The aim of th...
Nine patients (mean age 37 ± 16 years, range 14-57 years) were examined pre- and 12 months postoperatively for word recognition scores (WRS) at 65 dB SPL, sound-field (SF) thresholds, bone conduction ...
Due to avoidance of one surgical step, the surgical technique was simplified. Mean WRS in SF was 11.1 ± 22.2% (range 0-55%) pre- and 77.2 ± 19.9% (range 30-95%) postoperatively; mean SF threshold (pur...
Implant fixation by means of self-drilling screws was safe and effective in all nine patients. There was significant audiological benefit 12 months after implantation....
Clarifying the effect of each parameter of screw design on its fixation strength is critical in the development of any type of screw. The purpose of this study was to clarify the relationship between ...
Nine types of custom-made screws with the only changed variable being the thread depth were manufactured. Other elements were fixed at a major diameter of 4.5 mm, a thread region length of 15 mm, a pi...
Regardless of the foam-block density, the pull-out strength significantly increased as the thread depth increased from 0.1 mm to 0.4 mm; after that, the increase was more gradual (p < 0.01, respective...
The pull-out strength of 4.5-mm-diameter metal screws in a cancellous bone model was found to be biphasic, although linearly correlated with the change in screw depth in both phases. The boundary of t...
Thanks to new digital technologies, complex cases of severe maxillary atrophy may now be treated with additively manufactured subperiosteal implant structures (AMSISs). However, there are few studies ...
A specialized system for accurate self-tapping medical bone screw testing is developed, fully meeting the requirements of ASTM F543-A4 (YY/T 1505-2016). The onset of self-tap is identified automatical...
To radiographically analyze the effects of tenting screw technique (TS) and onlay bone grafts (OG) in horizontal bone augmentation....
Patients receiving horizontal bone augmentation by TS or OG were selected. The clinical outcomes and cone beam computed tomography (CBCT) data were documented pre-grafting, immediately post-grafting, ...
A total of 25 patients and 41 implants were involved in this study, with no grafting failures observed in either the TS group (n = 20) or the onlay group (n = 21). Volumetric bone resorption rate in t...
Both TS and OG achieved satisfactory bone augmentation effects, yet TS resulted in more bone augmentation and better stability than OG, with a reduced use of autogenous bone. Overall, the tenting scre...
Plate fixation of anterior pelvic ring fractures is often a vital component when surgically treating unstable pelvis fractures. Certain plate and screw configurations can have premature implant loosen...
A proximal femoral nail using a helical blade (HB) is commonly utilized to treat proximal femoral fracture but cut through failure of the lag screws is one of the devastating complications following t...
In revision surgery with significant segmental acetabular defects, adequate implant selection and fixation methods are critical in determining successful bony ingrowth. Commercially available total hi...
We prepared 40 synthetic bone models of the male pelvis. In half of the samples with acetabular defects, identical curvilinear bone defects were manually created using an oscillating electrical saw. O...
The average torsional strengths were significantly higher in the spread-out group over the brim-focused group regardless of the presence of the segmental defect of the acetabulum (p < 0.001). But for ...
Constructs of multi-hole acetabular cups with the spread-out screw holes configuration exhibited statistically better axial torsional strength and coronal lever-out strength. With the presence of post...
Reconstruction techniques for anterior glenoid bone loss have seen a trend from screws to suture-based fixations. However, comparative biomechanical data, including primary fixation and glenoid-graft ...
Suture-based bone block cerclage (BBC) and suspensory suture button (SB) techniques provide similar primary fixation and cyclic stability to double-screw fixation but with higher contact loading at th...
Controlled laboratory study....
In total, 60 cadaveric scapulae were prepared to simulate anterior glenoid bone loss with coracoid autograft reconstruction. Graft fixation was performed with 3 different techniques: (1) an interconne...
Initial graft compression was higher with screw fixation (141 ± 5 N) compared with suture-based fixations (...
Both SB and interconnected cerclage fixation improved dynamic contact loading compared with screw fixation in a biomechanical glenoid bone loss model. Cerclage fixation was biomechanically comparable ...
Suture-based bone block fixations improved graft-glenoid contact loading, but the overall clinical consequence on healing remains unclear....
The use of degradable magnesium screws to fix the bone flap implanted in the treatment of femoral head necrosis has achieved preliminary good therapeutic results. However, there is no conclusive evide...
To investigate the clinical efficacy and safety of biodegradable magnesium screws in pedicled vascularized iliac bone graft transfer (PVIBGT) for osteonecrosis of the femoral head (ONFH)....
A total of thirty-six patients (37 hips) with ONFH were recruited from March 2020 to July 2022. The study used a single-blind method, and patients who underwent PVIBGT were randomized into three group...
There was no statistically significant difference among these three groups in terms of types, gender, age, course of disease, surgical side, operation time, the length of stay (P > 0.05). All patients...
PVIBGT has a positive effect, especially with regard to improving blood supply of the femoral head. The fixation of biodegradable magnesium screws is reliable and safe in PVIBGT, and promote angiogene...