Key Laboratory of Clinical Diagnosis and Treatment Technology for Animal Disease, Ministry of Agriculture, Hohhot 010018, China. liushuying1968@imau.edu.cn.
Ege University Faculty of Science Department of Biology Molecular Biology Section, İzmir, Türkiye; Ege University Vaccine Development Application and Research Center, İzmir, Türkiye.
Laboratory of Anatomy and Physiology of Farm Animals, Department of Animal Science, Agricultural University of Athens (AUA), Iera Odos 75 str., 11855 Athens, Greece.
Laboratory of Anatomy and Physiology of Farm Animals, Department of Animal Science, Agricultural University of Athens (AUA), Iera Odos 75 str., 11855 Athens, Greece.
An experiment with controllable boundaries was designed to assess the influence of the recording angle and distance on two-dimensional (2D) imaging in laryngoscopy and resulting 2D parameter calculati...
Two high-speed camera setups were used to synchronously record an oscillating synthetic vocal fold (VF) model, simulating a high-speed videoendoscopy. One camera recorded at variable lateral recording...
The visual perception of a laryngoscopy was found to be influenced by the lateral recording angle, which may lead to misinterpretation of VF symmetry among inexperienced observers. The strongest influ...
The recording angle in 2D laryngoscopy should be carefully considered during visual inspection of the VF dynamics. Most of the investigated objective parameters were unaffected by the examined perspec...
https://doi.org/10.23641/asha.23961183....
To establish easily measurable and reproducible preoperative parameters predicting difficult laryngeal exposure in direct laryngoscopy. A prospective study including 71 patients who underwent transora...
To assess the efficacy and safety of visual rigid laryngoscopy and video laryngoscopy and to provide clinical information for developing a more suitable intubation tool for elderly patients....
In 75 consecutive elderly patients undergoing elective surgery in a single institution, tracheal intubation was randomly performed by 2 experienced anaesthesiologists using visual rigid laryngoscopy (...
The intubation times were 35.0 (30.0-41.5) s and 42.5 (38.0-51.3) s in Groups I and II, respectively (P < 0.001). The difference in direct complications between the two groups was statistically signif...
Compared with that of video laryngoscopy, the intubation time of visual rigid laryngoscopy in elderly patients was shorter. At the same time, visual rigid laryngoscopy reduced the incidence of immedia...
ChiCTR2100054174....
This article describes an anesthetic technique that induces temporary adductor vocal fold paresis and dense sensory loss of the posterior glottis. This method allows for improved precision of treatmen...
After introducing an adult video laryngoscope (VL) in our physician-paramedic prehospital and retrieval medical service, our quality assurance process identified this blade being used during pediatric...
We performed a retrospective review of intubated patients 15 years or younger in our electronic quality assurance registry from January 1, 2017, to December 31, 2020. Data collected were demographic d...
Ninety-nine pediatric patients were intubated, 67 (67%) by CMAC4 and 32 (33%) by DL. Video laryngoscopy had a first-attempt success rate of 96% and DL 91%. A Cormach and Lehane view 1 or 2 was found i...
Adult VL became the most common method of intubation in patients older than 1 year during the study period. An adult C-MAC4 VL could be considered for clinicians who prefer VL when a pediatric VL is u...
Video laryngoscopy (VL) has been proposed to increase the likelihood of successful intubation in patients with predicted difficult airways such as those with Pierre Robin sequence (PRS). Prior studies...
Participants were administered a 5-minute refresher video on 2 VL techniques (CMAC, conventional geometry VL, and McGrath, unconventional geometry VL) and DL. The participants were asked to intubate t...
Seventeen of 23 residents succeeded in intubating the PRS model using DL. Only 9 residents succeeded in intubating the PRS model using VL (conventional or unconventional geometry). Intubation success ...
Contrary to expectation, the intubation success rate was lower using VL than with DL among pediatric residents. This should be considered when designing residency training and in real-life resuscitati...
Establishment of a secure airway is a critical part of neonatal resuscitation in the delivery room and the neonatal intensive care unit. Videolaryngoscopy has the potential to facilitate successful en...
To determine the effectiveness and safety of videolaryngoscopy compared to direct laryngoscopy in decreasing the time and attempts required for endotracheal intubation and increasing the success rate ...
In November 2022, we updated the search for trials evaluating videolaryngoscopy for neonatal endotracheal intubation in CENTRAL, MEDLINE, Embase, CINAHL, and BIOSIS. We also searched abstracts of the ...
gov; www.controlled-trials.com), and reference lists of relevant studies....
Randomized controlled trials (RCTs), quasi-RCTs, cluster-RCTs, or cross-over trials, in neonates (0 to 28 days of age), evaluating videolaryngoscopy with any device used for endotracheal intubation co...
Three review authors performed data collection and analysis, as recommended by Cochrane Neonatal. Two review authors independently assessed studies identified by the search strategy for inclusion. We ...
The updated search yielded 7786 references, from which we identified five additional RCTs for inclusion, seven ongoing trials, and five studies awaiting classification. Three studies were included in ...
Videolaryngoscopy may increase the success of intubation on the first attempt and may result in fewer intubation attempts, but may not reduce the time required for successful intubation (low-certainty...
Determine the ideal head position to optimize visualization of the subglottis using flexible laryngoscopy....
Prospective cohort study....
Outpatient multidisciplinary airway clinic at a tertiary care center....
Patients presenting to a multidisciplinary airway clinic undergoing nasoendoscopic airway examination were enrolled. Three head positions were utilized to examine the subglottis during laryngoscopy: "...
One hundred patients participated. No statistical differences existed among in-clinic or blinded reviewers for the CL score in any head position (p = .35, .5, respectively). For both AG and VAS, flexe...
Both flexion and stoop postures can be implemented by an experienced endoscopist in awake, transnasal flexible laryngoscopy to enhance visualization of the subglottic airway....
This study aimed to describe how video laryngoscopy is used outside the operating room within the hospital setting. Specifically, we aimed to summarise the evidence for the use of video laryngoscopy o...
Preoperative evaluations of difficult airways are imperative, especially in newborns. The hyomental distance is a reliable index for predicting difficult airways in adults. However, few studies have e...
A prospective observational clinical study....
Newborns aged 0 to 28 days undergoing oral endotracheal intubation with direct laryngoscopy for elective surgery under general anesthesia were enrolled. The hyomental distance and hyoid level tissue t...
A total of 123 newborns were recruited for our study. The incidence of poor visualization of the larynx during laryngoscopy in our study was 10.6%. The multifactor logistic regression results showed t...
It is noninvasive and feasible to accurately measure the hyomental distance with ultrasound in newborns, and the results are reliable. We believe that the hyomental distance measured with ultrasound c...